Connecting The Line Interface - Black Box ME0004C-G703 Manual

High-speed 2-wire short-range dsl line driver
Table of Contents

Advertisement

E.5.3 C
ONNECTING THE
The 10BASE-T Ethernet rear card must be used with a front function card. There
are two essential requirements for connecting the line interface on the rear card.
1. These units work in pairs with one rear card connected to another rear card
over 2- or 4-wire twisted pair (2- or 4-wire operation is determined by the front
function card).
2. To function properly, the rear card needs one or two twisted pairs of metallic
wire (2- or 4-wire). The twisted pairs must be unconditioned, dry, metallic
wire, between 19 (0.9 mm) and 26 AWG (0.4 mm). Standard dial-up
telephone circuits that run through signal equalization equipment, or
standard, flat modular telephone type cable are not acceptable. See
Figure E-7.
APPENDIX E: 10BASE-T Ethernet Rear Card Module
Rear Card
RJ-45 Pin No.
1 (TD+)
2 (TD-)
3 (RD+)
6 (RD-)
Figure E-6. Crossover cabling.
L
I
INE
NTERFACE
Figure E-7. RJ-45 line interface.
10BASE-T DTE
RJ-45 Pin No.
1 (TD+)
2 (TD-)
3 (RD+)
6 (RD-)
- - - - - - - - - - - - - - - - - 1 Not connected
- - - - - - - - - - - - - - - - - 2 Not connected
- - - - - - - - - - - - - - - - - 3 (4-wire RX-)
- - - - - - - - - - - - - - - - - 4 (2-wire Tip) (4-wire TX+)
- - - - - - - - - - - - - - - - - 5 (2-wire Ring) (4-wire TX-)
- - - - - - - - - - - - - - - - - 6 (4-wire RX+)
- - - - - - - - - - - - - - - - - 7 Not connected
- - - - - - - - - - - - - - - - - 8 Not connected