Adjustment - KERN HFM Service Manual

Crane scale
Table of Contents

Advertisement

4 Adjustment

Switch-on balance and during the self test press the ZERO and the
button once at the same time. „P1 - - - "is displayed.
Enter password:
Select standard password „
Pressing the
by one.
Pressing the HOLD button moves the digit.
or
personal password, see function „F8 Ci"
or
supervisor password „
Confirm with ZERO button, the first function „F0 di" is displayed.
0
Press the
Press the ZERO button, „UnLD" will be displayed.
Unload the balance and wait until the LED
Press the ZERO button, the currently set adjustment weight is displayed.
In order to change, select the number to be changed using the HOLD button and
set the desired value using the
flashes.
Confirm by the ZERO button, „Load" will be displayed.
Attach the adjustment weight and wait until the LED
Press the ZERO button.
After successful adjustment the balance carries out a selftest, then it
automatically returns to weighing mode.
An adjusting error or incorrect adjusting weight will be indicated by the error
message; repeat adjustment procedure
HFM-SH-e-1110
000
".
button increases the numerical value of the blinking digit
315
"
button repeatedly until „F9 CL" will be displayed.
lights up.
button, the respective active digit
lights up.
9

Advertisement

Table of Contents
loading

Table of Contents