Fans And Airflow; Power; Storing Components - Dell EMC Virtual Edge Platform 1405 Series Getting Started Manual

Hide thumbs Also See for Virtual Edge Platform 1405 Series:
Table of Contents

Advertisement

Figure 8. VEP1405 rack installation - front and back view

Fans and airflow

Fan installation is done as part of the factory install and is based on the stock keeping unit (SKU) type. The VEP1405 supports a DC fan
unit with fan airflow starting from the bottom of the unit:
Four core unit with single fan
Eight core unit with two fans
Sixteen core unit with two fans
Position the unit in a well ventilated environment with clearance around the exhaust vents. The fan speed varies based on internal
temperature monitoring. The platform never intentionally turns off the fans.
CAUTION:
The fans are not field-replaceable.
CAUTION:
For thermal considerations, do not stack the VEP1405 platforms on top of each other. Do not place the
external power supply on top of the VEP1405 unit. Stacking the units or placing the power supply on top of a unit
impairs cooling.

Power

Connect the platform to the applicable power source using the appropriate power cable. The VEP1405 ships with one external AC/DC
power supply and one AC power cable.
When installing AC platforms, follow the requirements of the National Electrical Code ANSI/NFPA 70, where applicable.
The platform is powered-up when the power cable is connected between the platform and the power source.
CAUTION:
Before servicing, ensure that the power cable is disconnected.
CAUTION:
Use the power supply cable as the main disconnect device. Ensure that the socket-outlet is located near the
equipment and is accessible.

Storing components

If you do not install the VEP1405 and components immediately, properly store the platform and all optional components following these
guidelines:
The storage temperature range is from -40°C to 70°C (-40°F to 158°F) with humidity at 5% to 90% noncondensing
Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts
Store in a dust-free environment
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground
strap when handling the platform and its accessories. After you remove the original packaging, place the VEP1405 and
its components on an antistatic surface.
8
Site preparations

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vep1405

Table of Contents