Summary of Contents for Dell EMC SD-WAN Edge 600 Series
Page 1
Dell EMC SD-WAN Edge 600 Series Installation Guide August 2019...
Page 2
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Contents 1 About this guide........................... 5 Related documents................................5 Information symbols................................5 2 SD-WAN Edge 600 Series......................7 Introduction.................................... 7 Features....................................8 Physical dimensions................................9 LEDs......................................9 Edge 600 Series configurations............................10 Prerequisites..................................10 3 Site preparations.........................11 Site selection..................................11 Platform mounting................................11 Fans and airflow...................................
Page 4
Japan VCCI compliance for class A equipment......................27 Korean certification of compliance..........................28 Mexican certification of compliance..........................28 Taiwanese certification of compliance........................28 Singapore certification of compliance.........................28 Product recycling and disposal............................29 7 Dell EMC support........................30 Contents...
NOTE: Read this guide before unpacking the device. For unpacking instructions, see Unpack. Regulatory Marketing model Dell EMC SD-WAN Edge 600 Series (610, 620, 640, and 680) are represented by the regulatory model E24W and the regulatory type E24W001. Topics: •...
Page 6
NOTE: The ESD Warning icon requires that you take electrostatic precautions when handling the device. About this guide...
SD-WAN Edge 600 Series The Dell EMC SD-WAN Edge 600 Series (610, 620, 640, and 680) simplifies SD-WAN integration into your IT solution. It connects the service provider edge or small-to-medium branch locations to the cloud to host virtual network functions. The Edge 600 Series with 10/30/50/100/200/500 Mbps and 1/5/10 Gbps comes with VeloCloud software preinstalled.
Link up, 10 Gbps (for SFP+) green/ amber): Solid amber Link up, 100 Mbps (for SFP) Solid amber Link up, 1 Gbps (for SFP+) Link down Right side Solid green No activity (green): Blinking green Activity SD-WAN Edge 600 Series...
Site preparations Edge 600 Series installation. • Dell EMC SD-WAN Edge 600 Series (610, 620, 640, or 680) platform • AC country- and regional-specific cable to connect the AC power source to each of the AC power supplies • Rubber feet for desktop use and wall mount accessories •...
Ensure that you install in the platform in a grounded rack. Ground the rack to the same ground point the power service in your area uses. The ground path must be permanent. Dell EMC recommends you ground your platform. Connect the grounding cables as described in Edge 600 Series installation.
Fans and airflow Fan installation is done at the factory. The Edge 600 Series supports forced airflow from the sides and back of the enclosure. • Two-core—no fan • Four-core—single fans • Eight-core—two fans • Sixteen-core—two fans Position the platform in a well-ventilated environment with clearance around the exhaust vents. The fan speed varies based on internal temperature monitoring.
Before unpacking the platform, inspect the container and immediately report any evidence of damage. When unpacking the platform, make sure that the following items are included: • One Dell EMC SD-WAN Edge 600 Series platform • MiniUSB console cable •...
Page 14
WARNING: When mounting the Edge 640 or Edge 680 platform to the wall, face the Ethernet ports up towards the ceiling and the system status LED panel down, facing the floor. NOTE: When driving the screws into the bracket and platform, verify that you torque to 5 lb-in. NOTE: When mounting the platform to the wall using the included wall mount brackets, you do not need to remove the rubber pads from the bottom of the platform.
Keyhole-shaped bracket installation 4. Using a torque screwdriver, attach the wall mount brackets to the platform using the four M3 screws included. 5. Anchor the screws into the wall surface. 6. Place the pre-installed platform brackets over the wall-mounted screws. Slide the platform to one side to secure the platform in place. WARNING: When mounting the Edge 640 or Edge 680 platform to the wall, face the Ethernet ports up towards the ceiling and the system status LED panel down, facing the floor.
Optics modules The Edge 610 and Edge 620 platforms have SFP ports. The Edge 640 and Edge 680 platforms have SFP+ ports. To support 1 Gbps mode, the Edge 600 platform supports Dell EMC SFP 1 Gbps optic modules. •...
3. If you received an email from your IT administrator, follow the instructions in the email to complete the Edge activation. If you did not receive an email, request the setup instructions for your IT administrator or contact your Dell EMC sales representative.
Page 18
4. Connect local devices such as computers and switches to the GE1 or GE2 ports, or through the Edge WiFi. • GE1 or GE2 After following these instructions, if you are still unable to activate the Edge, contact your Dell EMC sales representative. Edge 600 Series installation...
User interface You can access the Edge 600 Series platform user interface (UI) at https://edge.velocloud.net or at the default IP address of 192.168.2.1 using one of the default LAN ports, GE1 or GE2, or through the WiFi connection. The WiFi default SSID is shown on the Overview page under Switched Interfaces / Wireless. This SSID defaults to velocloud-XXX where XXX is the last 3 digits of the serial number.
From the Properties page, you can view status information and change the connection properties. For example, you can specify a static IP address for the interface, or select a PPPoE for the connection. However, Dell EMC recommends entering static and PPPoE values using the Device Settings override on the VeloCloud Orchestrator.
Reset settings The Reset Settings page has the following buttons: • Identify—Flashes the platform lights for 30 seconds to help you locate the Edge. • Restart Service—Restarts the VMware SD-WAN by VeloCloud service. • Reboot—Initiates a reboot of the platform. When the service light illuminates again, the device has completed the reboot process. •...
Feature Specification Operating relative humidity 5% to 85% (RH), non-condensing continuously 5% to 90% (RH), non-condensing short term (< 1% of operational hour per year) Storage relative humidity 5% to 90% (RH) Operating altitude Maximum: 10,000 feet (3,048 meters) No performance degradation up to 3,117 feet (950 meters) IEEE standards The Edge 600 Series complies with the following IEEE standards: •...
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Caution: 1.
This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell EMC cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of this product, including the fitting of non-Dell EMC option cards.
(VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. NOTE: Use the AC power cords with Dell EMC equipment only. Do not use Dell EMC AC power cords with any unauthorized hardware. Figure 3. Japan: warning label...
Korean certification of compliance Korean certification of compliance Figure 4. Korean package label Radio compliance certificate Korea (Korean warning statement is only required for devices contain 2400~2483 and/or 5725~5825 MHz radios) 해당 무선설비는 운용 중 전파혼신 가능성이 있음 Korean radio compliance certificate Mexican certification of compliance Mexican compliance.
WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. Dell EMC products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE.
The Dell EMC support site provides integrated, secure access to these services. To access the Dell EMC support site, go to www.dell.com/support/. To display information in your language, scroll down to the bottom of the web page and select your country from the drop-down menu.