Summary of Contents for Dell EMC PowerEdge MX5016s
Page 1
Dell EMC PowerEdge MX5016s and MX5000s Installation and Service Manual Regulatory Model: E04B Series and E21M Series Regulatory Type: E04B002 and E21M001 July 2020 Rev. A01...
Page 2
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Contents Chapter 1: About this document....................... 5 Chapter 2: System overview......................6 Dell EMC PowerEdge MX5016s sled overview......................... 6 Inside the sled...................................6 Front view of the sled..............................7 Locating the Service Tag of your system........................7 System information label..............................8 Dell EMC PowerEdge MX5000s SAS IOM overview....................... 8 Front view of PowerEdge MX5000s module.......................9...
Page 4
LED indicators................................39 Chapter 7: Documentation resources....................40 Chapter 8: Getting help......................... 42 Contacting Dell EMC................................42 Documentation feedback..............................42 Accessing system information by using QRL........................42 Quick Resource Locator for the PowerEdge MX5016s system................43 Receiving automated support with SupportAssist ......................43 Contents...
About this document This document provides an overview about the storage sled and SAS IOM module, information about installing and replacing components, technical specifications, and guidelines to be followed while installing components. About this document...
Dell EMC PowerEdge MX5016s sled overview The PowerEdge MX5016s is a Storage Sled installed in the PowerEdge MX7000 enclosure to provide disk expansion for PowerEdge MX series Compute Sleds. In the PowerEdge MX7000 enclosure, the PowerEdge MX5016s is connected through an internal SAS fabric (Fab- C).
Front view of the sled Figure 2. Front view of the sled 1. Drive status indicator 2. System health and system ID indicator 3. Drive drawer release latch 4. Sled removal hatch 5. Sled release lever 6. Information tag panel Locating the Service Tag of your system You can identify your system using the unique Express Service Code and Service Tag.
The Dell EMC PowerEdge MX5000s is a redundant, hot-swappable SAS switch solution for the Dell EMC PowerEdge MX7000 enclosure that is designed to be used with the Dell EMC PowerEdge MX5016s storage sleds and SAS controllers that are installed in compute sleds.
Front view of PowerEdge MX5000s module Figure 4. Front view of the PowerEdge MX5000s module 1. Information tag 2. External SAS ports (1 & 2) 3. External SAS ports (3, 4, 5 & 6) 4. Release lever button NOTE: The external ports are not enabled for the current release.
After you receive your PowerEdge MX5016s system, you must set up your system in the enclosure. NOTE: If your storage sled is shipped installed in the enclosure, Dell EMC recommend that you remove the sled before you install the enclosure on the rack, to reduce chassis weight.
The Fab-C Mezz controller can be either PERC H745P MX, or HBA330 MMZ. Enclosure assignment mode is required if the PowerEdge MX5016s is to be shared between multiple compute sleds (that is clustered). Only HBA330 MMZ controller supports shared assignments.
Page 12
• Drive-Assigned mode assigns the individual drive from the PowerEdge MX5016s to another compute sleds (but cannot be assigned to more than one sled simultaneously). The Fab-C Mezz controller on the mapped compute sled can be either a PERC H745P MX, or HBA330 MMZ.
Page 13
Figure 6. Drive-Assigned mode Initial system setup and configuration for MX5016s...
Installing and removing system components This section provides information about installing and removing the storage sled components. For information about removing and installing the compute sled components, see the relevant sled Installation and Service Manual at www.dell.com/poweredgemanuals. Topics: • Safety instructions •...
Figure 8. Removing a sled from the enclosure Next steps Replace the sled into the enclosure or sled blank. Installing the sled into the enclosure Prerequisites 1. Follow the safety instructions listed in Safety instructions on page 14. 2. Remove the blank if installed. 3.
Figure 9. Installing the sled into the enclosure Next steps Restart the compute sled using the OpenManage Enterprise- Modular interface and assign the storage sled if not already assigned and power on the compute sleds to which the storage sled is mapped. Drive drawer NOTE: The enclosure fans may spin at a higher speed, to provide extra cooling when the drive drawer is opened.
Figure 10. Opening the drive drawer Next steps Remove or install the following components as applicable: • Remove a hard drive blank install a hard drive blank • Remove a hard drive carrier install a hard drive carrier • Remove an expander module install an expander module Closing the drive drawer Prerequisites...
Page 19
Figure 11. Closing the drive drawer Installing and removing system components...
Drives MX5016s supports sixteen hot-swappable 2.5-inch SAS drives. Drives numbered 0 through 9 are located on the left side of the enclosure, and 10 through 15 are located on the right side of the enclosure. Figure 12. Drive numbering Removing a drive blank Prerequisites 1.
Figure 13. Removing a drive blank Next steps Installing a drive carrier. Installing a drive blank Prerequisites NOTE: Ensure that the hard drive blanks are installed for the proper airflow if hard drives are not installed in the sled. 1. Follow the safety guidelines listed in Safety instructions on page 14.
Figure 14. Installing a drive blank Next steps Close the drive drawer. Removing a drive carrier Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 14. Open the drive drawer. 3. Using the management software, prepare the drive for removal. for more information about management software, see OpenManage Enterprise-Modular User's Guide www.dell.com/openmanagemanuals >...
Figure 15. Removing a drive from drive slot Next steps Install a drive blank Install a drive carrier Close the drive drawer. CAUTION: Sled drawer should not be open for more than three minutes while the enclosure is on due to maintain proper thermal temperature.
Figure 16. Installing a drive carrier Removing a drive from the drive carrier Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 14. Open the drive drawer. 3. If you are replacing an existing drive, use the management software to prepare the drive/SSD for removal. For more information about management software, see the OpenManage Enterprise Modular User's Guide available at www.dell.com/openmanagemanuals >...
Next steps Replace the drive. Installing a drive into the drive carrier Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 14. Open the drive drawer. Remove the drive carrier from the drive slot. Steps 1. Insert the drive into the drive carrier with the connector end of the drive towards the back of the carrier. 2.
Removing an expander module Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 14. Open the drive drawer. CAUTION: The sled is not designed to function on a single expander module. It is mandatory that both the modules be present in the sled for optimum performance.
Installing an expander module Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 14. Open the drive drawer. Steps 1. Align the expander card to the connector slot. 2. Press the expander card lever down until it firmly seats into the expander slot. Figure 21.
Figure 22. Removing a blank from Fabric C slot Next steps Install the module in the Fabric C slot blank. Installing a MX5016s blank in Fabric C slot Prerequisites 1. Follow the safety guidelines listed in Safety instructions. Remove the module from Fabric C slot.
Figure 23. Installing a blank in Fabric C slot Removing a MX5016s module from Fabric C slot Prerequisites NOTE: MX5016s storage sled does not support single SAS IOM configuration. 1. Follow the safety guidelines listed in Safety instructions. 2. If applicable, disconnect the cables that are connected to the modules. Steps 1.
Figure 24. Removing a MX5016s module from Fabric C slot Next steps Install a module into Fabric C Install a blank. 2. Connect the cables to the module. Installing a MX5016s module into Fabric C slot Prerequisites 1. Follow the safety guidelines listed in Safety instructions.
Page 31
Figure 25. Installing a MX5016s module into Fabric C slot Next steps 1. Connect the cables to the module. NOTE: Ensure that the SAS IOMs have the same firmware version. The OpenManage-Enterprise modular User interface OpenManage Enterprise-Modular User's Guide . allows you to view the firmware details.
Storage expander specifications The storage expander modules provide the storage subsystem for the drives in the PowerEdge MX5016s. The SAS expanders each connect to ports on all 16 HDDs. The first expander connects to port A of the first eight HDDs and port B of the second eight HDDs. The second expander is the opposite and connects to port B of the first eight HDDs and port A of the other eight HDDs.
Support for 7.2 K RPM 2.5-inch NearLine SAS drives NOTE: SATA and NVMe drives are not supported but mixing of rotational and SSD SAS drives is supported. Module dimensions Table 3. Dimensions of the Dell EMC PowerEdge MX5016s and MX5000s System Height Width...
Table 8. Maximum shock specifications Maximum shock Specifications Operating One shock pulse in the positive z axis of 31 G for 2.6 ms in the operational orientation. Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Particulate and gaseous contamination specifications The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions.
System diagnostics and indicator codes The diagnostic indicators on the system front panel display system status during system startup. Topics: • PowerEdge MX5016s System diagnostics and indicators • PowerEdge MX5000s System diagnostics and indicator codes PowerEdge MX5016s System diagnostics and...
Page 37
Figure 26. Drive status LED indicator Table 16. Drive status LED indicator Drive status indicators Condition Blinks green (On 250 ms Off 250 ms) Identifying drive or preparing for removal Slot empty Blinks green (500 ms), amber (500 ms), and turns off one Predicted drive failure second Blinks amber (On 150 ms Off 150 ms)
Expander health status indicators Expander health status indicator indicates the health condition of the expander module and identification indicator helps to locate a particular expander card within the storage sled. Figure 27. Expander health indicators Table 17. Expander health status indicators Indicator, Icon Description...
PowerEdge MX5000s System diagnostics and indicator codes LED indicators The Dell EMC PowerEdge MX5000s LED indicators indicate the health condition of the PowerEdge MX5000s module and identification indicator helps to locate a particular PowerEdge MX5000s module. Figure 28. Dell EMC PowerEdge MX5000s LED indicators Table 18.
To view the document that is listed in the documentation resources table: • From the Dell EMC support site: 1. Click the documentation link that is provided in the Location column in the table. 2. Click the required product or product version.
Page 41
Dell OpenManage Enterprise, see OpenManage Enterprise the Dell OpenManage Enterprise User’s Guide. For information about installing and using Dell www.dell.com/serviceabilitytools SupportAssist, see the Dell EMC SupportAssist Enterprise User’s Guide. For information about partner programs enterprise www.dell.com/openmanagemanuals systems management, see the OpenManage Connections Enterprise Systems Management documents.
The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell EMC Global Technical Support team. Documentation feedback You can rate the documentation or write your feedback on any of our Dell EMC documentation pages and click Send Feedback to send your feedback. Accessing system information by using QRL You can use the Quick Resource Locator (QRL) located on the information tag in the front of the MX5016s, to access the information about the Dell EMC PowerEdge MX5016s.
Receiving automated support with SupportAssist Dell EMC SupportAssist is an optional Dell EMC Services offering that automates technical support for your Dell EMC server, storage, and networking devices. By installing and setting up a SupportAssist application in your IT environment, you can receive the following benefits: •...
Need help?
Do you have a question about the PowerEdge MX5016s and is the answer not in the manual?
Questions and answers