3-2 Operation at Charging

3-2-1 Conditions To Start Charging

When the following conditions are satisfied, the MODE MI-COM (IC100) to start charging.
Conditions
Main unit power is turned OFF.
Battery is installed.
DC JACK is inserted.
DC JACK input voltage is 8.4±0.3V.
CHAPTER 2. TECHNICAL DESCRIPTION
Detection
MODE MI-COM pin 76/77
MODE MI-COM pin 88
(BATT INFO AD)
MODE MI-COM pin 71
(DC JACK DET)
MODE MI-COM pin 87
(BATT AD)
MODE MI-COM pin 73
(UNREG DET)
2-8
ZR70 MC A, ZR65 MC A, ZR60 A
Source of detection
POWER SW
Battery D terminal
(CN3202 pin 2)
DC JACK
(CN3201 pin 3)
DC JACK
(CN3201 pin 2)