Item
FORMAT
TALK OFF INCOM1
TALK OFF INCOM2
MIC1 GAIN
MIC1 LINE LV
MIC1 AMP
MIC2 GAIN
MIC2 LINE LV
MIC2 AMP
SHOOTING MODE
CAM FAN
TALLY GUARD
ASU FILTER
ASU MODE
ASU M. PED TARGET
REF.RECALL
CABLE CONNECT
HEAD PW
VF PW
CTRL ROTATION
TALLY CONTROL
TALLY INPUT
Set the camera format. When the unit is connected to a CCU, this item is only displayed and cannot be
changed.
Sets TALK for INCOM1 to OFF.
Sets TALK for INCOM2 to OFF.
Makes coarse adjustments of the MIC1 gain.
Adjusts the level for input to the camera's <MIC 1> connector.
Makes fine adjustments of the MIC1 gain.
(1 dB increments)
Makes coarse adjustments of the MIC2 gain.
Adjusts the level for input to the camera's <MIC 2> connector.
Makes fine adjustments of the MIC2 gain.
(1 dB increments)
Sets the shooting mode.
Sets the camera's cooling fan operation.
When set to ON, this function disables automatic ASU, AWB, ABB operation while the tally is ON.
Sets the operation of the ND/CC filter when auto setup is started.
REF
The filter stored in the reference file is used when operation starts.
CURRENT
Auto setup starts at the filter position made prior to startup.
Selects the auto setup mode setting.
Sets the position where the master pedestal is to be converged when auto setup is started.
Sets the reference file that is recalled when the [REF. RECALL] button is pressed.
Displays the CCU connection cable setting. You can change the setting via menu operations on the cam-
era itself.
HYBRID
Indicates that the CCU is connected via an optical fiber multi cable.
FIBER
Indicates that the CCU is connected via an optical fiber cable.
Use this button to control camera power remotely. However, control will not be possible unless the CCU
and the camera are turned on.
Each press of the button turns the power of the camera on or off.
Use this button to control the viewfinder power remotely. When the camera is turned on by the unit, the
viewfinder is also turned on.
Each press of the button turns the power of the viewfinder on or off.
A mode that operates based on the numerical value and a mode that operates based on the effect are
available. For details, refer to the operating instructions of the camera.
Sets whether or not to notify the camera when there is a tally input from the <PREVIEW> connector.
When this set to "ON", notification is sent if there is a tally input when the camera set in [TALLY INPUT] is
selected.
This is enabled when other than "Serial", "LAN", "Serial(AK)", and "LAN(AK)" is set in [CONNECT
SETTING].
Sets the camera to be notified of a tally input when [TALLY CONTROL] is set to "ON".
This is enabled when other than "Serial", "LAN", "Serial(AK)", and "LAN(AK)" is set in [CONNECT
SETTING].
Setting details