  • Page 1 Remote Operation Panel AK-HRP931P Before attempting to connect, operate or adjust this product, please read these instructions completely.
  • Page 2 Safety precautions CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
  • Page 3: Table Of Contents

    Contents Overview ... 3 Accessories ... 3 Operating precautions ... 4 Parts and their functions ... 5 ROP operation panel ... 5 ROP connector panel ... 16 Connections ... 16 System component connections ... 16 Reference files ... 16 Calling reference files ... 16 Storing reference files ...
  • Page 4: Operating Precautions

    Operating precautions ≥ The panel’s power is supplied from the camera control unit (AK-HCU931P). ≥ Handle the panel carefully. Dropping the panel or subjecting it to strong impact may cause malfunctioning and failures. ≥ Operate the panel within a temperature range of 32 °F to 104 °F (0 °C to 40 °C). Operation in locations below 32 °F or above 104 °F may adversely affect the internal parts.
  • Page 5: Parts And Their Functions

    Parts and their functions ROP operation panel When any of the panel switches is pressed, the buzzer sounds. However, the buzzer does not sound when the panel's ON switch lamp is off or when BUZZ OFF has been selected on the FUNC menu.
  • Page 6 Parts and their functions 2 Auto black balance switch [AUTO BLACK] This is used to automatically adjust the black balance. Lighted: This indicates that the automatic black balance adjustment has started. Flashing: This indicates that the automatic black balance adjustment ended without being completed. Off: This indicates that the automatic black balance adjustment was completed correctly.
  • Page 7 Parts and their functions 1 5600K switch [5600K MODE] This is used to change the amplification rate of the GBR signals by an electrical circuit to achieve a white balance that corresponds to the color temperature of 5600K. When it is pressed, the B video signal is attenuated by approximately -6 dB, the R video signal is boosted by approximately 3 dB, and the G video signal is not attenuated.
  • Page 8 Parts and their functions VPAR: Vertical parabola correction This is used to correct the coloring of black screen images in the vertical direction in the range of –100 to 100. When the numerical setting is incremented, the video level at the top and bottom of the screen is increased.
  • Page 9 Parts and their functions 9 Flare control switch [FLARE CONTROL] This is selected to change the amount of flare correction. When it is selected, its lamp lights. R F L R G F L R B F L R RFLR, GFLR, BFLR These adjust the R, G or B flare in the range of –100 to +100, and at 0 the flare correction operation is turned off.
  • Page 10 Parts and their functions –CLP: Detail edge undershoot clip This is used to limit the length of the undershoot parts of the detail edge components. +KNE: Detail edge overshoot knee This function applies the knee to the detail edge overshoot parts.
  • Page 11 Parts and their functions +CLP: Detail edge overshoot clip This is used to limit the length of the overshoot parts of the detail edge components. –CLP: Detail edge undershoot clip This is used to limit the length of the undershoot parts of the detail edge components.
  • Page 12 Parts and their functions DCLK: Down-conversion link This is used to decide whether to go with the down- conversion system control based on the AUX external input or set the down-conversion independently. UCLK: Up-conversion link This is used to decide whether to go with the up- conversion system control that is linked to the down- conversion system...
  • Page 13 Parts and their functions POWER (FAN): Fan power switch This is used to set the power of the camera head’s fan to ON, OFF, or AUTO. SPEED (FAN): Fan speed This is used to set the speed of the camera head’s fan. 2D-M: Component 2-dimensional low-pass filter This is used to set whether to apply the 2-dimensional low- pass filter to the SDTV component output.
  • Page 14 Parts and their functions Calling scene file data 1. From among the 1 to 8 scene file switches, press the number of the switch that corresponds to the scene file which is to be called and light its lamp. 2. The scene file is now read. The data read from the scene file is input into the current file and then output.
  • Page 15 Parts and their functions R, G, B gain controls [R, G, B GAIN] These are used for the red (R), green (G) and blue (B) adjustments of the white balance. When the auto white balance can be performed and the R, G or B gain control is turned, the gain control value on the LCD display changes.
  • Page 16: Rop Connector Panel

    RCP connector The remote control panel (RCP) is connected here. PREVIEW Preview control connector [PREVIEW] This is the output connector which is used for previewing. When the joystick is pushed in, the contact information is output. AK-HCU931P ROP cable PREVIEW AK-HRP931P...
  • Page 17: External Dimension Drawings

    External dimension drawings Specifications Power supply: DC 12 V (DC 10 V to 17 V) (Supplied from CCU) Power consumption: 6 W indicates safety information. CCU control: RCP control: PREVIEW control: Maximum cable extension distance: Operating temperature range: Storage temperature range: Operating ambient humidity: Dimensions (W k H k D): Weight:...
  • Page 18 PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7000 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835...