I N S T A L L A T I O N I N S T R U C T I O N S
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construction
codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures for custom matrix designs to
any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST
be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the
combined weight of the fixture(s), clamps, cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F (-10° to 45°C).
Do not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas were
unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing, or serving.
Overhead fixture installation must always be secured with a secondary safety attachment, such as an
appropriately rated safety cable that can hold 10 times the weight of the fixture.
Allow approximately 15 minutes for the fixture to cool before servicing.
TO MAINTAIN IP65 RATING INTEGRITY, AND PREVENT WATER FROM ENTERING
FIXTURE, ALL UNUSED CONECTION RUPPER CAPS MUST BE SEALED.
SEAL  ALL  UNUSED  
CONNECTIONCAPS  
SEAL   ALL   UNUSED  
CONNECTIONCAPS  