Installation manual
Mori HR
Read this manual carefully before using the product and keep it
in a safe place for reference.
This product was constructed up to standard and in compliance
with regulations relating to electrical equipment and must be
installed by technically qualified personnel.
The manufacturer assumes no responsibility for damage to
persons or property resulting from failure to observe the
regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
• T he device should not be used for applications other than those specified in this manual.
• A fter removing the product from its packaging, verify its condition. In case of doubt,
contact a qualified technician. Do not leave packaging within the reach of small children
or people with disabilities.
• D o not touch the appliance with wet or damp hands/feet.
• T his appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
• D o not use the product in the presence of inflammable vapours, such as alcohol,
insecticides, gasoline, etc...
• I f any abnormalities in operation are detected, disconnect the device from the mains
supply and contact a qualified technician immediately. Use original spare parts only for
repairs.
• T he electrical system to which the device is connected must comply with regulations.
• B efore connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not,
contact a qualified technician.
• T he device should not be used as an activator for water heaters, stoves, etc., nor
should it discharge into hot air/fume vent ducts deriving from any type of combustion
unit. It must expel air outside via its own special duct.
• O perating temperature: -20°C up to +50°C.
• T he device is designed to extract clean air only, i.e. without grease, soot, chemical or
corrosive agents, or flammable or explosive mixtures.
• D o not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
• D o not immerse the device or its parts in water or other liquids.
• T urn off the main switch whenever a malfunction is detected or when cleaning.
• F or installation an omnipolar switch should be incorporated in the fixed wiring, in
accordance with the wiring regulations, to provide a full disconnection under overvoltage
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mori HR Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ELTA FANS Mori HR Series

  • Page 1 Installation manual Mori HR Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
  • Page 2: Technical Specifications

    category III conditions (contact opening distance equal to or greater than 3mm). • I f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. • D o not obstruct the fan or exhaust grille to ensure optimum air passage. • E nsure adequate air return/discharge into/from the room in compliance with existing regulations in order to ensure proper device operation. • I f the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation. INTRODUCTION MORI HR is a continuously running, alternate flow supply and extract fan with heat retention for use in habitable rooms such as; living rooms, bedrooms, dining rooms basements and hallways. It is designed to ensure adequate ventilation in enclosed environments. It is recommended that two units are installed in a pair: when one unit is...
  • Page 3: Operation

    OPERATION Every 70 seconds the unit alternates between being a supply fan and an extract fan. During the extract mode the units high efficiency heat exchanger collects and retains heat from the extracted air, it then transfers the majority of this heat to the incoming air during supply mode, recovering most of thermal energy which would be otherwise lost in the ventilation process. The unit can be run continuously at a set speed by adding an internal link, or controlled via the dedicated controller, 149-SEN-CTRLS which allows speed selection and triggering of free cooling mode. “S1” “S2” Operation “S3” Operation Heat recovery Speed 1 (Alternate flow) Speed 2 Free cooling Speed 3 S3 switch activates the “Free cooling “ (Bypass) mode , which stops alternate flow and keeps the fan in “extract-only” or “intake-only” mode, to avoid the heat exchange when necessary. To set the extract-only” mode or “intake-only”, place the integral jumpers as per Fig. 20A or Fig. 20B).The front cover LED indicates when the Free cooling mode is on. An automatic “Boost”mode can be achieved through a dedicated switch or room sensors like 149-SEN-HY, 149-SEN-PIR or 149-SEN-CO2. Wiring configurations: 1. Constant run with alternate flow and heat retention on Speed 1 only (Fig. 18A). 2. Constant run with alternate flow and heat retention on Speed 2 only (Fig. 18B). 3. Constant run with alternate flow and heat retention on Speed 3 only (Fig. 18C). 4. Constant run with alternate flow and heat retention on Speed 1 with boost to Speed 3 triggered by external switching device (ordered separately if required) (Fig. 18D). 5. Constant run with alternate flow and heat retention on Speed 2 with boost to Speed 3 triggered by external switching device (ordered separately if required) (Fig. 18E). 6. Operation using controller 149-SEN-CTRLS (ordered separately if required) (Fig. 18F).
  • Page 4: Jumper Position

    OPTION 2: If two or more units are not connected under the same main switch, to reset the synchronisation, press at the same time the black pin of each unit (Fig. 32-33) at least 3 seconds. SYNCHRONISATION IN CASE OF INSTALLATION WITH CONTROLLER If two or more units are controlled by means of the same controller (149-SEN-CTRLS or similar), they always operate in a synchronised way. Wiring diagram as per Fig. 18. JUMPER POSITION Integral jumper set in position A (Fig. 20A) means “extract” mode. Intergal jumper set in position B (Fig. 20B) means “intake” mode. The jumper position defines both the air-flow direction when the unit is activated for the first time (for the synchronisation) and the air-flow direction of the free-cooling mode. MAINTENANCE AND SERVICE Maintenance can be carried out by the user as indicated at page 11. Service must be perfmormed only by technically qualified personnel in accordance with local rules and regulations. Make sure that the mains supply to the unit is disconnected (page 12). Cleaning of the heat exchanger can be performed from outside as well.
  • Page 5: Installation

    INSTALLATION Mori HR 100 - Mori HR 150 CONTENUTO IMBALLO MODELLO MORI HR min. 108mm HR100 min. 158mm HR150 INDOOR OUTDOOR insulation foam =Ø 8x10mm =Ø 5x40mm...
  • Page 6 100mm HR100 115mm HR150...
  • Page 7 SPEED 1 (FIXED) SPEED 2 (FIXED) SPEED 3 (FIXED) SPEED 1 to 3 SPEED 2 to 3 CTRL-S...
  • Page 8 CTRL-S CTRL-S FOGLIO ISTRUZIONI - AGGIUNTA FOGLIO ISTRUZIONI - JUMPER POSITION A JUMPER POSITION B INTAKE EXTRACT...
  • Page 9 CLICK...
  • Page 10 EXTERNAL GRILLE Ø 5x40mm 3-5mm TO RESET OF THE SYNCHRONIZATION OF THE UNITS (OPTION 1) TO RESET OF THE SYNCHRONIZATION OF THE UNITS (OPTION 2)
  • Page 11: Filter Cleaning (Maintenance)

    FILTER CLEANING (MAINTENANCE) Can be carried out by the user...
  • Page 12 HEAT EXCHANGER CLEANING (SERVICE) Must be carried out only by technically qualified personnel...
  • Page 13 100mm HR100 115mm HR150 REMOTE CONTROLLER (on request) HIGHLY RECOMMENDED Fig. 57 149-SEN-CTRLS...
  • Page 14 ErP Directive - Regulations 1253/2014 1254/2014 a) Mark ELTA FANS b) Model MORI HR 100 MORI HR 150 c) SEC class c1) SEC warm climates kWh/m2.a -15,6 -16,2 c2) SEC average climates kWh/m2.a -37,5 -38,2 c3) SEC cold climates kWh/m2.a...
  • Page 15: Standard Conformity

    STANDARD CONFORMITY 2014/35/EU Low Voltage Directive (LVD) 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following standards: Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2 Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2(2015); EN 61000-3- 2(2014); EN 61000-3-3(2013). DISPOSAL AND RECYCLING Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device.
  • Page 16 Elta Fans Limited Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom T: +44 (0) 1384 275800 F: +44 (0) 1384 275810 E: bs@eltafans.co.uk 000830 - 07 - 0718...

This manual is also suitable for:

Mori hr 100Mori hr 150

Table of Contents