Introduction
CETO100 (fig. 1) is a centrifgual fan designed to ensure
air extraction in small/medium-sized rooms such as bathrooms, toilets and kitchens.
Suitable for air discharge through long length ducting.
Wall or ceiling installation, surface or recessed in plasterboard walls (fig.2).
Read this manual carefully before using the product and keep it in a safe place for reference.
This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by techni-
cally qualified personnel.
The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this
booklet.
TECHNICAL SPECIFICATIONS
• Material: High quality, impact and UV-resistant ABS colour RAL 9010
• Design front cover removable for cleaning without the use of tools
• Highly quality forward-curved impeller for high performance and top silence.
• Single phase 2-speed motor with integral thermal protection.
• Motor mounted on ball bearings that guarantee a longer product life cycle (30,000 h) and suitable for cold climates
• The fan is double insulated: no earth connection is required
• Suitable for continuous or intermittent operation
• IPX4 degree of protection
• Power supply 220V to 240V~ 50/60Hz
Airflow
(max)
Model
L/s
m
/h
3
CETO100
28.8/17.3 104/62
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
• The device should not be used for applications other than those specified in this manual.
• After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging
within the reach of small children or people with disabilities.
• Do not touch the appliance with wet or damp hands/feet.
• The device is not intended for use by persons (including children) with reduced physical, sensory or mental capacities or those with a lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the device from a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the device.
• Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.
• If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use
original spare parts only for repairs.
• The electrical system to which the device is connected must comply with regulations.
• Before connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
• The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from
any type of combustion unit. It must expel air outside via its own special duct.
• Operating temperature: 0°C up to +50 °C.
• The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
• Do not immerse the device or its parts in water or other liquids.
• Turn off the main switch whenever a malfunction is detected or when cleaning.
• For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full
disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
Static pressure
Power
Sound pressure
Pa max
W max
dB(A) @3m
251/142
28/17
38/27
Fig. 1

Advertisement

Table of Contents
loading

Summary of Contents for ELTA FANS CETO100

  • Page 1 Installation manual CETO100 - Centrifugal fan Introduction CETO100 (fig. 1) is a centrifgual fan designed to ensure Fig. 1 air extraction in small/medium-sized rooms such as bathrooms, toilets and kitchens. Suitable for air discharge through long length ducting. Wall or ceiling installation, surface or recessed in plasterboard walls (fig.2).
  • Page 2: Standard Conformity

    • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. • Do not obstruct the fan or exhaust grille to ensure optimum air passage. •...
  • Page 3 INSTALLATION (Fig.2) perimetrical exhausting wall - surface wall - recessed ceiling - surface (accessory on demand) ceiling - recessed...
  • Page 4 MOUNTING CETO100 = Ø 96mm...
  • Page 5: Surface Installation

    SURFACE INSTALLATION SURFACE CABLE H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm 3 x Ø 5mm ~ 5mm ~ 150mm...
  • Page 6 SURFACE INSTALLATION RECESSED CABLE ENTRY H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm 3 x Ø 5mm ~ 150mm...
  • Page 7 WIRING DIAGRAM: PAGE 17...
  • Page 8: Recessed Installation

    RECESSED INSTALLATION 233 mm RECESSED CABLE ENTRY H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 9÷40 mm 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm...
  • Page 9 ~ 150mm...
  • Page 10 WIRING DIAGRAM: PAGE 17...
  • Page 11: Electrical Wiring

    ELECTRICAL WIRING CETO100 Vmax CETO100 Vmin PULL CORD PULL CORD CETO100C Vmax CETO100C Vmin...
  • Page 12 ROSSO - RED - ROUGE - ROJO ROSSO-RED-ROUGE-ROJO CETO100T-HT Vmax CETO100T-HT Vmin ROSSO - RED - ROUGE - ROT ROSSO-RED-ROUGE-ROT PULL CORD PULL CORD CETO100HTC Vmax CETO100HTC Vmin TIMER TIMER...
  • Page 13: Maintenance & Cleaning

    MAINTENANCE / CLEANING...
  • Page 16: Disposal And Recycling

    Improper disposal of the product by the user may result in administrative sanctions as provided by law. Elta Fans Limited Building Services 46 Third Avenue...

Table of Contents