Download Print this page

Advertisement

Quick Links

G
Installation manual
MORI dMEV II 150HT - dMEV unit
Read this manual carefully before using the product and keep
it in a safe place for reference.
This product was constructed up to standard and in compliance
with regulations relating to electrical equipment and must be
installed by technically qualified personnel.
The manufacturer assumes no responsibility for damage to
persons or property resulting from failure to observe the
regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
• T he device should not be used for applications other than those specified in this manual.
• A fter removing the product from its packaging, verify its condition. In case of doubt,
contact a qualified technician. Do not leave packaging within the reach of small children
or people with disabilities.
• D o not touch the appliance with wet or damp hands/feet.
• T his appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
• D o not use the product in the presence of flammable vapours, such as alcohol,
insecticides, gasoline, etc.
• I f any abnormalities in operation are detected, disconnect the device from the mains
supply and contact a qualified technician immediately. Use original spare parts only for
repairs.
• T he electrical system to which the device is connected must comply with regulations.
• B efore connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not,
contact a qualified technician.
• T he device should not be used as an activator for water heaters, stoves, etc., nor
should it discharge into hot air/fume vent ducts deriving from any type of combustion
unit. It must expel air outside via its own special duct.
• O perating temperature: 0°C up to +50°C.
• T he device is designed to extract typical household air only, i.e. without excessive
grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
• D o not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
• D o not immerse the device or its parts in water or other liquids.
• T urn off the main switch whenever a malfunction is detected or when cleaning.
• F or installation an omnipolar switch should be incorporated in the fixed wiring, in
accordance with the wiring regulations, to provide a full disconnection under overvoltage
category III conditions (contact opening distance equal to or greater than 3mm).
• I f the supply cord is damaged, it must be replaced by the manufacturer, its service
Fig. 1
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the MORI dMEV II 150HT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ELTA FANS MORI dMEV II 150HT

  • Page 1 Installation manual MORI dMEV II 150HT - dMEV unit Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
  • Page 2: Technical Specifications

    Attention: do not mount the product on the window without this kit. INTRODUCTION MORI dMEV II 150HT (fig. 1) is a decentralised mechanical ventilation unit designed to ensure air extraction, in small/medium sized rooms such as bathrooms, toilets and kitchens..
  • Page 3 MORI dMEV II 150HT Factory setting: 6l/s VERSIONS MORI dMEV II 150HT (Humidity control version) The fan comes complete with an adjustable humidity sensor and adjustable timer. The humidity threshold is adjustable from 50% to 95% Relative Humidity via a dedicated trimmer, and the timer is adjustable from 0 - 30 minutes via a dedicated trimmer (fig.
  • Page 4: Standard Conformity

    STANDARD CONFORMITY 2014/35/EU Low Voltage Directive (LVD) 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following standards: Electrical Safety EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2. Electromagnetic Compatibility EN 55014-1(2017); EN 55014-2(2015); EN 61000-3-2(2014); EN 61000-3-3(2013). INSTALLATION (Fig.2) perimetrical exhausting wall ceiling (accessory included in the box) window (kit on demand) direct exhausting short ducting...
  • Page 5 MOUNTING AND ELECTRICAL WIRING...
  • Page 6 SURFACE CABLE 4 x ø 5 mm H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm cavo a parete Ø10mm...
  • Page 7 RECESSED CABLE ENTRY 4 x ø 5 mm H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm vo a parete cavo sottotracci The ceiling mounting gasket should be sandwiched between the fan and For window mounting instruction please see the individual installation...
  • Page 8 JUMPER INSTALLATION AIRFLOW 1 2 3 through wall 6L/s through wall 8L/s  TIMER through wall 13L/s  through wall 15L/s   through wall 17L/s  through wall 21L/s   through wall 25L/s   through wall 29L/s ...
  • Page 9: Maintenance & Cleaning

    MAINTENANCE / CLEANING The unit should be cleaned regularly as explained in this leaflet to maintain performance and warranty cover. Cleaning should be carried out as and when required but please note intervals between cleaning should not exceed 12 months. The installer should explain this cleaning regime to the homeowner/occupier and ask the homeowner/occupier to keep a record of the cleaning done on this leaflet as this will be required to be provided by the homeowner/occupier to claim against any product failure under warranty.
  • Page 10: Disposal And Recycling

    DISPOSAL AND RECYCLING Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device.
  • Page 11 ErP Directive - Regulations 1253/2014 1254/2014 a) Mark ELTA FANS MORI dMEV II 150 HT b) Model c) SEC class c1) SEC warm climates kWh/m2.a -11,1 c2) SEC average climates kWh/m2.a -25,5 c3) SEC cold climates kWh/m2.a -50,6 Energy label...
  • Page 12 Elta Fans Limited Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom T: +44 (0) 1384 275800 F: +44 (0) 1384 275810 E: bs@eltafans.co.uk 004467 - 00 - 0719...

This manual is also suitable for: