Pentair FLECK 5812 XTR Installer Manual page 64

Hide thumbs Also See for FLECK 5812 XTR:
Table of Contents

Advertisement

Installer Manual Fleck 5812 - XTR - Programming
From the home screen, press the settings button
Press day override/time-driven and use the arrows
regeneration in which a new regeneration will automatically be run whether one is scheduled or not.
Press regen. time and use the arrows
cycle will begin.
Press hardness and use the arrows
the hardness of the incoming untreated water supply.
Note
If immediate volumetric regeneration has been set, regeneration time will have no influence
on it and regeneration will start as soon as capacity end.
Note
Changing the hardness setting recalculates treatment volume and regeneration interval.
This setting should only be changed on the advice of a professional.
Note
The hardness parameter is not accessible in timeclock and filter mode.
Press
to save your changes or press
Note
Additional features may be accessed from the Settings screen by pressing the buttons at the
bottom of the screen:
Master settings:
Brightness:
64 / 132
to access the settings screen.
Settings
day override/
time-driven
regen. time
hardness
to adjust the time of day when an automatic regeneration
to adjust the hardness setting. This value should match
to return to the home screen without saving.
Displays the master settings screen, which allows you to fully
program the valve.
Displays the brightness screen, which allows you to adjust the
backlight brightness of the controller screen.
1 d
02:00 am
300 mg/L
to adjust the number of days since last
Ref. MKT-IM-019 / E - 14.10.2019