Program Overview
20 sec. no activity
Retrieval mode
ID-Information
00 Current level
-1 History level 1
-2 History level 2
-3 History level 3
-4 History level 4
E1 Error inlet metre
E2 Error drainage metre

10 Troubleshooting

10.1 No water fl ow
Cause:
Water intake closed.
Troubleshooting:
Open water intake on the upstream stop valve or inlet valve
Caution: The following faults may be remedied only by trained and authorised personnel.
!
10.2 No or low water fl ow in spite of open water intake
Cause:
Mains pressure too low.
Troubleshooting:
Check mains pressure.
If the fault continues in spite of adequate mains pressure, check the fi lter
system and fi lter cartridge and change if necessary.
!
Operating and Safety Information (Chapter 3).
10.3 Leak at Screwed Connections
Cause:
Screwed connections not fi tted correctly.
Troubleshooting:
Check mains pressure. Check all screwed connections and mount according to
Chapter 4.
If the fault continues, exchange fi lter system.
!
Operating and Safety Information (Chapter 3).
34

Operating mode

Carbonate hardness • Ca-
pacity • By-pass • last fi lter
change date
1 x button
Caution: Prior to changing, read the Technical Data (Chapter 12) and the
Caution: Prior to changing, read the Technical Data (Chapter 12) and the
30 sec.no activity =
no Parameter acceptance
Press button 4 seconds
Parameterisation
Filter system type and size
Type of hardness (unit)
and value
Monthly limit
RESET
Parameter acceptance
2 sec.
2 sec.
2 sec.
2 sec.
on inlet hose
.