Operation - Hilti PP 10 Operating Instructions Manual

Pipe laser
Hide thumbs Also See for PP 10:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
6.8 Replacing the batteries in the PPA 20 remote
control unit
1.
The cover on the rear of the remote control unit
moves when pushed in the direction of the arrow.
Remove the cover in order to gain access to the
batteries.
6.9 Charging status
en
Charging status

7 Operation

7.1 Button functions 4
Plumb spot button
@
Laser beam mode button
;
"Lock" button
=
Target plate auto-centering
button
%
Direction control
&
Parameter selection
&
Automatic centering
&
Laser beam up / down
(
Value entry
(
SET button
)
ON / OFF button
+
7.2 Symbols in the display 5
Plumb spot indicator.
@
Alignment indicator
;
Battery status indicator
=
Self-leveling indicator
%
Inclination indicator
&
Percentage
(
Lock symbol
)
Electronic bubble level
+
Laser mode display
§
20
2.
Remove the 4 old batteries and replace them with
new ones.
3.
Push the cover back into position until it engages.
Red LED lights
Green LED lights
Blinks green
Blinks red
Switches the plumb spot on and off (switches off automatically after
30 minutes).
The laser beam can be switched over by pressing the laser beam mode
button. PP 10: constant beam or blinking beam PP 25: constant beam,
blinking beam, high-power mode
This button locks all data entry functions. Values can then no longer
be changed. The data entry functions can be unlocked by pressing the
LOCK button again.
The laser beam finds the center of the target plate automatically.
Moves the laser beam to the left or right.
Used to select the parameters to be set.
The laser beam centers itself automatically when both direction control
buttons are pressed at the same time.
Moves the laser beam up or down.
Positive or negative values may be entered. When both buttons are
pressed at the same time, inclination is set automatically to 00.000%.
This button is used to confirm the selected parameters.
This button is used to switch the tool on or off.
Shows that the plumb spot is active.
Indicates laser beam alignment.
Remaining battery capacity is shown in 3 levels.
Blinks while the laser is leveling itself. The display subsequently changes
to the laser mode set.
Shows the selected inclination.
Shows the unit of measurement selected (percentage or per thousand).
The values entered cannot be changed.
Shows whether the tool is leveled correctly.
The laser modes "blinking", "normal" and "high-power" (PP25) are
shown.
Charging
Charging completed
Error during charging
The protective cut-out has been activ-
ated. The PP 10/25 may be used while
in this status.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pp 25

Table of Contents