VCS VideoJet 1000 Manual page 70

Hide thumbs Also See for VideoJet 1000:
Table of Contents

Advertisement

Configuration with web browser
72
a motion alarm has been detected and to switch the light off again
at the end of the alarm.
Idle state:
Select Open if the relay is to operate as a normally open contact or
Closed if it is to operate as a normally closed contact.
Operating mode:
Select the operating mode for the relay.
If, for example, a lamp is switched on by an alarm and is to remain
on when the alarm has ended, select Bistable. If an acoustic signal
activated by an alarm is to remain on for a period of, for example,
10 sec, select Monostable 10 s.
Relay follows:
Select a particular event by which the relay is to be activated as
required. The following events can activate the relay:
Off: No relay triggering by events
Connection: Triggering if any connection is established
Video Alarm: Triggering caused by loss of the video signal
Input 1: Triggering caused by an external alarm sensor
Remote input: Triggering by a switching contact from a remote
location
Motion: Triggering by the motion alarm
Relay name:
The relay can be assigned a name from here. The name will be
shown on the Overview page and, dependent upon configuration,
also on the Live page.
Trigger relay:
Click on the button Relay to manually switch the relay (e.g. for test
purposes or to operate a door opener).