Configuration with web browser
Click on the button Select area, to configure the sensor cells. A
new window is opened up.
If necessary, click on the button Clear all first in order to clear the
current selection (cells indicated in red).
Using the left mouse button click in those cells which are to be acti-
vated. Activated cells are indicated in red.
If required, click on the button Select all to monitor the entire video
frame.
Using the right mouse button, click on those cells which are to be
deactivated. Inactivated cells are indicated in white.
Click on the button Set to store the configuration.
Click on the title bar of the window on the symbol X to close the win-
dow without storing any of the changes entered.
Local sensitivity
The basic sensitivity of the video sensor can be adapted for the
ambient camera conditions.
The sensor reacts to brightness variations in the video image. The
darker the observation range, the greater the value that must be
selected here.
Adjust the sensitivity by moving the slider to the desired setting with
the mouse key held down.
Average n [frames]
It is possible to define the number of frames during which a move-
ment is monitored in order to generate an alarm. In this way, it is
possible to prevent generating a false alarm, e.g. by a bird flying
across the surveillance area.
Select the desired value by moving the slider to the desired position
with the mouse key held down.