Installation
Installation
Installation
Intrinsically Safe
Safe
Intrinsically
Intrinsically
Safe
Do not substitute or modify system components
as this may impair intrinsic safety. For installation,
maintenance, or operation instructions, read
instruction manuals. Do not install equipment
approved only for non-hazardous location in a
hazardous location. See the identification label for
the intrinsic safety rating for your model.
The DCM and ADCM are designed for
use with Graco Control Architecture based
systems that have a compatible design. See
Appendix A - Control Drawing 16M169, page
for installation requirements and entity parameters.
332013E
Follow all installation instructions in your system
manual.
• Intrinsically safe (IS) equipment should not be used
with a power supply that has no barrier.
• Do not move units from a non-intrinsically safe
(non-IS) installation to an IS installation.
• IS equipment that has been used with a non-IS
power supply must not be returned to a hazardous
location.
• Always use an IS power supply with IS equipment.
Electrical Connections
Electrical
Electrical
Install per the control drawing in Appendix A.
13,
Connections
Connections
Installation
7