Siemens WF 725 Planning Instructions page 27

Equipment for machine tools: positioning modules
Table of Contents

Advertisement

08.90
The DB numbers are freely selectable. The number of DB axis and DBWF depends on the
number of WF axes (see planning instructions).
FBs:
FB207
Start functions
FB210
Main program
FB211
Start functions
FB215
Start functions
FB216
for a DUAL-PORT-RAM-Length of 16 Byte
FB217
for a DUAL-PORT-RAM-Length of 32/64 Byte
3.1.3 Note to the "Basic program" and "Package 1" of SINUMERIK 3
The user must call the blocks FB70 Menu selection (basic program) and FB77 Input/Output of
data (package 1). Hereby, the FB77 must be called before the FB70, and the D1.3 must be set
back in DB9 shortly before calling FB70 (Therefore, DB9 must be loaded in the RAM area).
3.1.4 Overview of used data blocks
DB-No.
39
48
49
68
69
79
89
109
129
freely selectable
freely selectable
freely selectable
1) 2* number of magazine locations +20
2) 2* number of connected axes +11
©
Siemens AG 1990 All Rights Reserved
WF 725/WF726 (PJ – NC Auxiliary axis and Tool magazine for SINUMERIK 3GA4)
DB designation
MENU-DB
Format address list
Allocation address list
Format-DB
Allocation list
Display-DB
WZ-M-A1
WZ-M-A2
WZ-M-A3
DBZU of basic functions
DBWF of basic functions once
for each module
DB-Achse of basic functions
once for each axis
6ZB5 440-0JB02
Technical Data
Length in words
Memory type
EPROM
165
EPROM
19
EPROM
19
RAM
245
RAM
37
RAM
261
RAM
1)
RAM
1)
RAM
1)
RAM
2)
RAM
128
RAM
64
3 - 3