5. INSTALLATION

5.1 Mechanical installation

-
The terminal is designed for indoor installation only.
-
Select premises with low temperature variations and far from any electromagnetic
interference sources (contactors, motors, other badge swipe readers, etc.).
-
Open the terminal with the key [A].
-
Remove connector [J] and unclip the front panel of the terminal.
-
Remove the the protection plate [C] by loosening the 2 screws and by sliding it upwards.
-
Fasten the back of the terminal where selected, using the 4 dowel pins and 4 screws
supplied.

5.2 Electrical installation

With the system de-energized, connect the contacts of the relay (230 V, 4A
[B1].
For mains supply:
After de-energizing the relevant circuit-breaker / disconnecting switch, connect the 230 V
±10%50 Hz mains supply to the concentrator block [B2] (1.5 to 2.5 mm
neutral and earth wire, bare on a 5 mm length).
For low voltage power supply:
Connect a 12V
(11.5 to 15
DC
power supply be equipped with an off-mains operating battery, if necessary, connect the "mains
V
supply" signal (12
DC
Connect the low voltage power cord of concentrator block [B3] to the external electrical devices
(typically BODET Kar readers). The amperage supplied by the terminal on this concentrator block
is limited to 200 mA. The maximum voltage supplied is 14.5 V
Plug connector [H] from back-up battery [I] to the power-supply board.
) power supply to the concentrator block [B4]. Should the external
V
DC
= mains supply, 0 V
DC
= no mains supply).
.
DC
6
) concentrator block
max
2
cross-section phase,