Indoor Units
(d) Where flammable gas may leak, where there is carbon fiber, or ignitable dust suspension in the air, or where volatile
flammables such as thinner or gasoline are handled. Operating the unit in such conditions can cause a fire.
• Take adequate measures to prevent the outside unit from being used as a shelter by small animals. Small animals
making contact with electrical parts can cause malfunctions, smoke, or fire. Instruct the customer to keep the area
around the unit clean.
• Install the power supply and control wires for the indoor and outdoor units at least 3.5 feet away from televisions or
radios to prevent image interference or noise. Depending on the radio waves, a distance of 3.5 feet may not be sufficient
to eliminate the noise.
• Dismantling the unit, treatment of the refrigerant, oil and additional parts must be done in accordance with the
relevant local, state, and national regulations.
• Do not use the following tools that are used with conventional refrigerants: gauge manifold, charge hose, gas leak
detector, reverse flow check valve, refrigerant charge base, vacuum gauge, or refrigerant recovery equipment.
• If the conventional refrigerant and refrigerator oil are mixed in R-410A, the refrigerant may deteriorate.
• This air conditioner is an appliance that should not be accessible to the general public.
• As design pressure is 478 psi, the wall thickness of field-installed pipes should be selected in accordance with the
relevant local, state, and national regulations.
3.2

The Multi-Split Duct-Free System CTXS07JVJU, CTXS09/12HVJU

Mounting plate
A
Mounting plate fixing screws
B
3/16" × 1"L (M4 × 25mm)
C
Air-purifying filter with
photocatalytic deodorizing function
D
Wireless remote controller
• Before choosing the installation site, obtain user approval.
1.
Indoor unit.
The indoor unit should be sited in a place where:
1) The restrictions on installation specified in the indoor unit installation drawings are met.
2) Both air intake and exhaust have clear paths met.
3) The unit is not in the path of direct sunlight.
4) The unit is away from the source of heat or steam.
5) There is no source of machine oil vapor (this may shorten indoor unit life).
6) Cool air is circulated throughout the room.
7) The unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range.
8) The unit is at least 3.5 ft (1m) away from any television or radio set (unit may cause interference with the picture or sound).
2.
Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are
properly received by the indoor unit (within 23 ft (7m)).
246
Accessories
1
Remote controller holder
E
Fixing screws for remote controller
F
10
holder 1/8" × 13/16"L (M3 × 20mm)
2
G
Dry batteries AAA. LR03 (alkaline)
H
Indoor unit fixing screws
1
3/16" × 1/2"L (M4 × 12mm)
Choosing a Site
1
Operation manual
K
2
Installation manual
L
2
2
EDUS121131
1
1
Installation Manual