Advertisement

EDUS121131
3-3. Wall embedded piping.
Follow the instructions given under
Left-side, left-back, or left-bottom piping
1) Insert the drain hose to this depth so it won't be
pulled out of the drain pipe.
4.
Wiring.
1) Strip wire ends. (9/16 inch (15mm))
2) Match wire colours with terminal numbers on
indoor and outdoor unit's terminal blocks and
firmly screw wires to the corresponding terminals.
3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely
latched up.
5) In case of connecting to an adapter system.
Run the remote controller cable and attach the S21
connector as the illustration above.
6) Shape the wires so that the service lid fits securely, then close
service lid.
WARNING
1) Do not use spliced wires, strand wires, extension cords, or starburst connections, as they may cause overheating,
electrical shock, or fire. Follow all Local, and State electrical codes.
2) Do not use locally purchased electrical parts inside the product. (Do not overload the circuit by adding drain pump
or other electrical equipment to unit terminals.) Doing so may cause electric shock or fire.
3) When carrying out wiring connection, take care not to pull at the conduit.
5.
When connecting to an HA system.
1) Remove the front grille. (3 screws)
2) Remove the electrical
wiring box. (1 screw)
3) Remove the metal plate
electrical wiring cover. (4 tabs)
4) Attach the connection cord to
the S21 connector and pull
the harness out through the
notched part in the figure.
5) Replace the electrical wiring cover as it was, and
pull the harness around, as shown in the figure.
6.
Drain piping.
1) Connect the drain hose,
as described right.
2) Remove the air filters
and pour some water
into the drain pan to
check the water flows
smoothly.
Installation Manual
Indoor Unit Installation (3)
3) Remove the metal
Screw
plate electrical
wiring cover.
The drain hose should
be inclined downward.
No trap is permitted.
Do not put the end
of the hose in water.
Insert drain hose
to this depth so
it won't be pulled
out of drain pipe.
1-15/16"
(50mm)
or more
Outer wall
Terminal block
1
2
3
Electrical component box
Shape wires so that the service
lid will fit securely.
Use the specified wire type.
When wire length exceeds
33ft (10m), use AWG14 wires.
3
Indoor
2
1
unit
Push
Tab
Push
Slide
HA connector
(S21)
Main body
Metal plate
electrical cover
4)
Attach the connection cord to
the S21 connector and pull the
Push
harness out through the
notched part in the figure.
Tab
3) When drain hose
Indoor unit
drain hose
requires extension,
obtain an extension
hose commercially
available.
Be sure to thermally insulate the indoor
section of the extension hose.
4) When connecting a rigid polyvinyl chloride pipe
(nominal diameter 1/2 inch (13mm)) directly to the drain
hose attached to the indoor unit as with embedded
piping work, use any commercially available drain
socket (nominal diameter 1/2 inch (13mm)) as a joint.
Drain hose supplied with
Commercially available drain socket
the indoor unit
(nominal diameter 1/2 inch (13mm))
Indoor Units
Inner wall
Drain hose
Vinyl chloride
drain pipe
(VP-30)
Back
Lock nut
Conduit
mounting
plate
Conduit
Outdoor unit
1 2 3
L
L
1
2
Use AWG16 or AWG14 wire
for the Interconnecting wires.
HA cord
Tab
Notched part
5)
Replace the electrical
wiring cover as it was,
and pull the harness
around, as shown
in the figure.
Extension drain hose
Heat insulation tube
(Field supply)
Commercially available rigid
polyvinyl chloride pipe
(nominal diameter 1/2 inch (13mm))
257