Download Print this page

Tascam CD-01U Specifications page 10

Control i/o terminals rs-232c protocol specifications
Hide thumbs Also See for CD-01U:

Advertisement

4-10. AUTO CUE LEVEL PRESET
Sets the Auto Cue level of the controlled device.
When this command is transmitted with request data ([FF]), the controlled device returns the AUTO
CUE LEVEL RETURN command [A0].
The Auto Cue function is turned on and off using the AUTO CUE SELECT command [30].
Command
Data
Return
Data 1
Data 2
Description
0
0
-24dB
0
1
-30dB
0
2
-36dB
0
3
-42dB
0
4
-48dB
0
5
-54dB
0
6
-60dB
0
7
-66dB
0
8
-72dB
F
F
Auto Cue level request
· If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-11. DIRECT TRACK SEARCH PRESET
Sets a track number. If the controlled device is in stop or play mode, the specified track is played back.
If the controlled device is in ready mode, the unit will enter ready mode at the start of the specified track.
This command is judged to be illegal if an attempt is made to jump to a non-existent track (e.g. track 11
on a 10-track disc).
Command
Data
Return
Description
Data 1
Tens digit of track number
Data 2
Units digit of track number
Data 3
Thousands digit of track number
Data 4
Hundreds of track number
· If the specified track number does not exist on the disc, the controlled device sends ILLEGAL [F2].
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
20
2 bytes
AUTO CUE LEVEL RETURN [A0]
Remarks
Sets the Auto Cue detect level to –24dB.
Sets the Auto Cue detect level to –30dB.
Sets the Auto Cue detect level to –36dB.
Sets the Auto Cue detect level to –42dB.
Sets the Auto Cue detect level to –48dB.
Sets the Auto Cue detect level to –54dB.
Sets the Auto Cue detect level to –60dB.
Sets the Auto Cue detect level to –66dB.
Sets the Auto Cue detect level to –72dB.
Requests the currently set the Auto Cue detect level.
23
4 bytes
None
10
Remarks
Track number
Sample) 2300: Track 23
TEAC Corporation