Synchronize Remote Control
The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use.
1. Insert alkaline batteries in the remote control
battery holder and handset. The battery holder is
located beside the receiver, near the control valve
under the fi rebox, left of the fi rebox or beside the
wall switch.
2. With a sharp object, press and hold the receiver's
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
June 2019
GV60 PLUS
3. Within the subsequent 20 seconds, press the small
fl ame button ( ) on the remote handset until you
hear two short beeps confi rming the sychronization
is set. If you hear one long beep, this indicates the
code learning sequence has failed or the wiring is
incorrect.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.