Remote Control Initial Set-up
The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use.
1. Insert alkaline batteries in the remote control
receiver and handset. The receiver is located left of
the control valve under the burner module.
2. With a sharp object, press and hold the receiver's
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
3. Within the subsequent 20 seconds, press the small
fl ame button (
) on the remote handset until you
hear two short beeps confi rming the sychronization
is set. If you hear one long beep, this indicates the
code learning sequence has failed or the wiring is
incorrect.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.
July 2018
GV60 MAX
with or without optional fan
1

Advertisement

Table of Contents
loading

Summary of Contents for Valor GV60 MAX

  • Page 1: Operation Manual

    GV60 MAX Electronic Ignition Remote Control used on Valor heaters of Series G3.5, G4, H5 and H6 For Valor heaters 700, 780, 785, 1100, 1150 and 1400 installed with or without a fan (blower) Remote Control Initial Set-up The receiver and the handset of the remote control sys- tem must be initially synchronized before the fi...
  • Page 2: Remote Control Operation

    Remote Control Operation Radio Frequency Current temperature Handset 315 MHz for USA and Canada. (F or C) sensor This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS Period standard(s). Operation is subject to the following two start or end Battery status (Temp, Timer)
  • Page 3: Modes Of Operation

    MODES OF OPERATION Press and hold (small fl ame) button to decrease fl ame height or to Briefl y pressing the SET button set the appliance at pilot fl ame. changes the mode of operation in the For fi ne adjustment tap the (large following order: fl...
  • Page 4: Circulating Fan Operation

    CIRCULATING FAN OPERATION - Nighttime Setback T E M P (if equipped) Temperature Mode (Appliance must be in standby mode; pilot ignited) - - Circulating Fan - The circulating fan has 4 The room temperature is measured speed levels from low (1 bar) to high (4 bars). and compared to the Nighttime Setback temperature.
  • Page 5: Setting The On / Off Temperatures

    SETTING THE ON / OFF TEMPERATURES SETTING THE “DAYTIME” TEMPERATURE SETTING THE “NIGHTTIME SETBACK” TEMPERATURE Default Settings: (sun), 23ºC / 74ºF TEMP Default Settings: (moon), “ ” (OFF) T E M P Briefl y press SET button to scroll to TEMP (sun) mode.
  • Page 6: Setting Program Timers

    SETTING P1 OFF TIME SETTING PROGRAM TIMERS You can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. Briefl y press SET button to scroll to TIMER (moon) while the time The Programs P1 and P2 must be set in the following fl...
  • Page 7: Automatic Shut-Off

    Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...

Table of Contents