Brine Tank, Brine Well, Safety Brine Valve And Air Check Cleaning - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer Manual Foleo - Maintenance

8.5.3. Brine tank, brine well, safety brine valve and air check cleaning

No.
Remove the softener cover, see 8.5.1. First steps, page 76 and 8.5.2. Softener cover
A
removal, page 77.
B
Turn the clips (11) 90 degrees, remove the cabinet plate and the brine well covers
Remove the safety brine valve clip (7) and free the brine valve tube (5) from the safety
C
brine valve (6).
D
Remove the brine tank (12) and brine well (8) from cabinet (3).
E
Transfer the remaining salt from brine tank (12) to a basket.
CAUTION
Do not lay down or flip over the softener to empty the brine tank.
Remove the nut (9) and remove the safety brine valve (6) and the air check (13) from the
F
brine well (8).
Clean the brine tank (12), the brine well (8), the safety brine valve (6), the air check (13)
G
and the salt funnel (1) with water and sponges.
H
Reverse above procedure steps to rebuild.
I
Fill the brine tank (12) with salt, see 8.3. Adding salt, page 75.
78 / 112