Set ID
- Use this function to specify a set ID number.
- Refer to 'Real Data Mapping 1'. See page 28.
1. Press the MENU button and then use
2. Press the
button and then use
G G
3. Press the
G G
button and then use
monitor ID number.
• The adjustment range of
4. Repeatedly
press the
Communication Parameters
• Baud rate : 9600 bps (UART)
• Data length : 8 bits
• Parity : None
* Use a crossed (reverse) cable.
Command Reference List
COMMAND 1 COMMAND 2
01. Power
02. Input Select
03. Aspect Ratio
04. Screen Mute
05. Volume Mute
06. Volume Control
07. Contrast
08. Brightness
09. Colour
10. Tint
11. Sharpness
12. OSD Select
13. Remote control lock mode
14. PIP/DW
15. PIP Position
16. Treble
17. Bass
18. Balance
19. Colour Temperature (CSM) k
20. Red Adjustment
21. Green Adjustment
22. Blue Adjustment
23. PIP input Select
24. Abnormal Status
25. ISM Method
26. Low Power
27. Orbiter Time Setting
28. Orbiter Pixel Setting
29. Picture Size
30. Auto Configure
31. Send IR Code
* When setting the 24 ~ 31, a menu doesn't display on screen.
24 PLASMA TV
button to select the SPECIAL menu.
D D / E E
button to select
D D / E E
F / G
button to adjust
is 1 ~ 99.
Set ID
MENU
button to return to normal viewing.
DATA
(Hexadecimal)
k
a
0 ~ 1
k
b
Refer to p. 25
k
c
Refer to p. 25
k
d
0 ~ 1
k
e
0 ~ 1
k
f
0 ~ 64
k
g
0 ~ 64
k
h
0 ~ 64
k
i
0 ~ 64
k
j
0 ~ 64
k
k
0 ~ 64
k
l
0 ~ 1
k
m
0 ~ 1
k
n
Refer to p. 26
k
q
0 ~ 3
k
r
0 ~ 64
k
s
0 ~ 64
k
t
0 ~ 64
u
0 ~ 3
k
v
0 ~ 50
k
w
0 ~ 50
k
$
0 ~ 50
k
y
Refer to p. 27
k
z
0 ~ a
j
p
0 ~ 3
j
q
0 ~ 1
j
r
1 ~ FE
j
s
1 ~ 3
j
t
0 ~ 20
j
u
1
m
c
Key Code
Set ID
.
Set ID
to choose the desired
• Stop bit : 1 bit
• Communication code : ASCII code
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1]
* [Command 2]
* [Set ID]
* [DATA]
* [Cr]
* [ ]
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The set transmits ACK (acknowledgement) based on this
format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The set transmits ACK (acknowledgement) based on this
format when receiving abnormal data from
non-viable functions or communication errors.
Data 1: Illegal Code
2: not support function
3: Wait more time
: First command to control Plasma
Monitor set.
(j, k, m or x)
: Second command to control Plasma
Monitor set.
: You can adjust the set ID to choose
desired monitor ID number in special
menu. Adjustment range is 1 ~ 99.
When selecting Set ID '0', every connected
Plasma Monitor set is controlled.
Set ID is indicated as decimal (1~99) on
menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
: To transmit command data.
Transmit 'FF' data to read status of
command.
: Carriage Return
ASCII code '0x0D'
: ASCII code 'space (0x20)'