5.2

SPECIFICATION FOR THE ELECTRICAL CONNECTION

EV Portable is designed for plug it in a CEE Industrial connector (female). You need to choose
the amps rate depending on the place where it is installed and the adaptor selected.
EV Portable needs to be connected to a main supply line and must be hardwired and
correspond to the nationally applicable legal conditions.
Selection of the RCD circuit breaker:
Each charging station must be connected to a separate RCD circuit breaker. No other
circuits may be connected to this RCD circuit breaker.
The nominal current I
Dimensioning the Line circuit breaker:
When dimensioning the line circuit breaker also observe the increased environmental
temperatures in the switching cabinet! Under certain circumstances, this may require
a reduction of the pre-adjusted charging current setting to increase the system
availability.
Maximum value according to the type plate data matching to the amp rate EV Portable
selected.
Dimensioning of the mains supply line:
When dimensioning the mains supply line also observe possible reduction factors and the
increased environmental temperatures in the interior connection area of the charging station
must be selected to match the line circuit breaker and the fuse.