4.8.4 Data Port

The system provides two standard RS232 serial ports to allow a computer to be connected for
data transfer and control purposes. Note that when connecting to a PC the connecting cable must
be a straight through RS232 cable.
Baud Rate, Parity, Databits and Stopbits
If you wish to connect a PC to Data port 1, you must ensure that the PC and the system are
identically configured. The available settings are:
Baud Rate
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity
None, Odd, Even
Databits
7, 8
Stopbits
1, 2
The control interface provided by the data port supports a subset of the Hayes command set as
well as a comprehensive set of system specific commands. It maintains communication with the
data port's command interpreter at all times. All features available from the hand-held remote
control can be accessed through the data port.