ABB C505 User Manual page 111

Control it 1/2 din advanced process controller, industrial it enabled
Table of Contents

Advertisement

Configuration Frames
Frame Title
A
Alarm 1 Hysteresis
Alarm 1 Trip
Alarm 1 Type
Alarm 2 Hysteresis
Alarm 2 Trip
Alarm 2 Type
Alarm 3 Hysteresis
Alarm 3 Trip
Alarm 3 Type
Alarm 4 Hysteresis
Alarm 4 Trip
Alarm 4 Type
Alarm 5 Hysteresis
Alarm 5 Trip
Alarm 5 Type
Alarm 6 Hysteresis
Alarm 6 Trip
Alarm 6 Type
Alarm 7 Hysteresis
Alarm 7 Trip
Alarm 7 Type
Alarm 8 Hysteresis
Alarm 8 Trip
Alarm 8 Type
Alarm Acknowledge Enable
Alarm Configuration
Analog I/P 1 Offset Cal
Analog I/P 1 Span Cal
Analog I/P 2 Offset Cal
Analog I/P 2 Span Cal
Analog I/P 3 Offset Cal
Analog I/P 3 Span Cal
Analog O/P 1 Electrical High
Analog O/P 1 Electrical Low
Analog O/P 1 Engineering High
Analog O/P 1 Engineering Low
Analog O/P 2 Electrical High
Analog O/P 2 Electrical Low
Analog O/P 2 Engineering High
Analog O/P 2 Engineering Low
Analog Output 1 Source
Analog Output 2 Source
Analog/Dig Output 1 Type
Analog/Dig Output 2 Type
Auto Selection Source
Auto/Manual Switch Enable
Autotune Password
Mnemonic
Number
HYS. 1
8. 0 3
trP. 1
8. 0 2
tYP. 1
8. 0 1
HYS. 2
8. 0 6
trP. 2
8. 0 5
tYP. 2
8. 0 4
HYS. 3
8. 0 9
trP. 3
8. 0 8
tYP. 3
8. 0 7
HYS. 4
8. 1 2
trP. 4
8. 1 1
tYP. 4
8. 1 0
HYS. 5
8. 1 5
trP. 5
8. 1 4
tYP. 5
8. 1 3
HYS. 6
8. 1 8
trP. 6
8. 1 7
tYP. 6
8. 1 6
HYS. 7
8. 2 1
trP. 7
8. 2 0
tYP. 7
8. 1 9
HYS. 8
8. 2 4
trP. 8
8. 2 3
tYP. 8
8. 2 2
FPAK
b. 0 3
LEV8, ALMS
8. 0 0
OFF. 1
E. 0 1
SPN. 1
E. 0 2
OFF. 2
E. 0 3
SPN. 2
E. 0 4
OFF. 3
E. 0 5
SPN. 3
E. 0 6
AN1H
C. 0 3
AN1L
C. 0 4
r1H
C. 0 5
r1L
C. 0 6
AN2H
C. 1 1
AN2L
C. 1 2
r2H
C. 1 3
r2L
C. 1 4
AN1A
C. 0 2
AN2A
C. 1 0
tYP. 1
C. 0 1
tYP. 2
C. 0 9
ASrC
A. 1 8
FP. A M
b. 0 1
A. P AS
b. 0 7
B
Basic Configuration
Bias Display Enable
C
Calibration
CJ Beta Value
CJ Reading - I/P1 & I/P2
CJ Reading - I/P3
CJ Reference Value
Configuration Password
Configured Output 1
Configured Output 2
Configured Output 3
Control Action
Control Configuration
D
Day Setting
Digital Output 1 Polarity
Digital Output 1 Source
Digital Output 2 Polarity
Digital Output 2 Source
F
Feedback Range High
Feedback Range Low
I
Input 1 Broken Sensor
Input 1 Decimal Point
Input 1 Engineering High
Input 1 Engineering Low
Input 1 Filter Time Constant
Input 1 Temp Units
Input 1 Type
Input 2 Broken Sensor
Input 2 Decimal Point
Input 2 Engineering High
Input 2 Engineering Low
Input 2 Filter Time Constant
Input 2 Temp Units
Input 2 Type
Input 3 Broken Sensor
Input 3 Decimal Point
Input 3 Engineering High
Input 3 Engineering Low
Input 3 Filter Time Constant
Input 3 Temp Units
Input 3 Type
FRAMES INDEX...
LEV6, APPL
6. 0 0
b. d IS
b. 0 6
LEVE, CAL
E. 0 0
bEtA
E. 1 4
CJ 1
E. 1 5
CJ 2
E. 1 6
rEF
E. 1 3
C. P AS
b. 0 9
C. O P. 1
A. 1 3
C. O P. 2
A. 1 5
C. O P. 3
A. 1 7
C. A Ct
6. 0 3
LEV. A
A. 0 0
dAY
b. 1 0
dG1P
C. 0 8
dG1A
C. 0 7
dG2P
C. 1 6
dG2A
C. 1 5
Fb. H I
E. 1 2
Fb. L O
E. 1 1
bSd. 1
7. 0 6
dP. 1
7. 0 3
EN1H
7. 0 4
EN1L
7. 0 5
FLt. 1
7. 0 7
UNt. 1
7. 0 2
tYP. 1
7. 0 1
bSd. 2
7. 1 3
dP. 2
7. 1 0
EN2H
7. 1 1
EN2L
7. 1 2
FLt. 2
7. 1 4
UNt. 2
7. 0 9
tYP. 2
7. 0 8
bSd. 3
7. 2 0
dP. 3
7. 1 7
EN3H
7. 1 8
EN3L
7. 1 9
FLt. 3
7. 2 1
UNt. 3
7. 1 6
tYP. 3
7. 1 5
107