Ambient conditions
Operating temperature range
Temperature behavior:
Temperature range for storage:
Rate of temperature change:
Permissible relative air humidity:
Altitude:

Standards and guidelines

National regulations (USA)
FCC Title 47, Part 15
NEC Article 625
National regulations (Canada)
CE Code CSA C22.1 No. 280
ICES-003
-30 °C to +50 °C (-22 °F to 122 °F)
without direct sunlight
This is not a safety device, merely an operating
function. The specified operating temperature
range must be complied with.
Within the specified operating temperature
ranges, the device provides the charging current
continuously.
To increase the charging availability, the charging
current specification is reduced to 16 A in the
event of prohibited exceeding of temperature.
A further consequence may be the shut-off of
the charging process. After cooling, the charging
process is continued, and the charging current
specification is increased again.
-30 °C to +80 °C (-22 °F to 176 °F)
max. 0.5 °C/min (max. 32.9 °F/min)
5 % to 95 % non-condensing
max. 6560 ft above sea level
Digital Device Class B
Electric vehicle charging systems
Electric Vehicle Supply Equipment
Class B