Installation

3.1

Transducer installation

Any orientation is permitted.
Mount the transducer on a level
surface of the machine using the
mounting brackets. Observe the
recommended spacing of the
mounting brackets.
1. Align transducer with sliding
rod.
2. Tighten mounting screws to a
maximum of 2 Nm.
Mounting brackets and M4 × 20 cylinder head
screws, DIN 912, max. tightening torque 2 Nm
Fig. 3-1: Dimensional drawing (BIW1...P1-S115 transducer)
Housing length
Mechanical zero point
Electrical zero point
Electrical stroke = mechanical stroke
Clamp spacing
Nominal length < 300 mm
Nominal length 300 mm to < 600 mm
Nominal length > 600 mm
Table 3-1: Dimensions
Ensure that no strong electrical
fields are present in the immedi-
ate vicinity of the transducer.
A = Nominal length + 100 mm
B0 = 0 + 2 mm
B0 + 5 mm
B = Nominal length + 10 mm
C = Nominal length - 20 mm
C = Nominal length - 15 mm
C = Nominal length - 10 mm
Available nominal lengths
➥ ➥ ➥ ➥ ➥ section 6.2
BIW1-...-M0100-P1-S115
Nominal length 100
BIW1-...-M0360-P1-S115
Nominal length 360
BIW1-...-M0750-P1-S115
Nominal length 750
Table 3-2: Examples
english
A = 200
B = 110
C = 80
A = 460
B = 370
C = 345
A = 850
B = 760
C = 740