MODEL 6416/6417
SERVICE/CALIBRATION MANUAL
CAT# 2141.01/2141.02

ENVIRONMENTAL CONDITIONS

Fig. 1
1. Domain of reference (CEI160).
2. Domain of operation.
3. Domain of storage (without batteries). According to CEI359 category II
(equipment for indoor and outdoor use).

MECHANICAL CHARACTERISTICS

Dimensions: 55x95x262mm (thickness, width, height).
Max. clamping diameter: 35mm.
Weight: approximately 935g with batteries.
Display unit: 152-segment OLED. Active surface area 48x39mm.
Tightness: IP40, group III equipment.
Drop test: according to IEC-61010-1.

COMPLIANCE WITH INTERNATIONAL STANDARDS

Device fully protected by double insulation .
NF-EN-61010-2-032 Ed 2012, 600V, CAT IV.

ELECTROMAGNETIC COMPATIBILITY

The device is compliant with standard IEC-61326-1.