Page 2
Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene Les pages de présentation contiennent principalement des images.
Page 4
Ø48 (2x) Seen from above - Connection above Seen from above - Connection below Fig. 2 Connections W Seen from above - Connection above Seen from above - Connection below Fig. 3 Connections E min 120 Fig. 4 Minimum mounting distance...
Page 5
Accessories SIRe SIReB SIReAC SIReAA SIReB SIReUR SIReRTX 70x33x23 mm 114x70x50 mm SIReUR SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReAC/SIReAA SIReCC610 10 m SIReCJ4/SIReCJ6 SIReCC615 15 m SIReCC403 SIReCC405 SIReCC410 10 m SIReCC415 15 m SIReRTX SIReCC VKF15LF DN15 VLSP VKF15NF DN15 VKF20...
Page 8
SIReB Basic SFS E SIReUB1 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
Page 9
SIReB Basic SFS W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM...
Page 10
5600 32,2 1,16 184,1 23,9 30,5 0,29 12,8 2500 14,6 0,17 14,7 35,2 0,18 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
Assembly and operating instructions General Instructions Ensure that the service hatch is accessible Read these instructions carefully before and can be fully opened. installation and use. Keep this manual for See Fig. 4. future reference. The product may only be used as set out in Electrical installation the assembly and operating instructions.
All units: Note that the unit shall be preceded by a Since fan motors and other components are regulating valve, see Frico valve kit. maintenance free, no maintenance other than Water connection can be made from above cleaning is necessary. The level of cleaning and below, according to the order key, via can vary depending on local conditions.
Page 14
Overheating Draining the water coil (W) The air curtain unit with electric heater is The drain valve is on the underside of the equipped with an overheat protector. If it is coil. It can be accessed via the service hatch. deployed due to overheating, reset as follows: 1.
Page 15
Safety • For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used. • Keep the areas around the air intake and exhaust grilles free from possible obstructions! • The unit may have hot surfaces during operation and when cooling down! •...
Page 19
Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...
Need help?
Do you have a question about the SFS Series and is the answer not in the manual?
Questions and answers