7. Technical data

Ambient temperature Ta:
Storage temperature:
Charging temperature:
Power supply:
Period of operation:
Charging time:
Dimensions:
Frequency range:
Sensitivity:
Channels:
Channel grid:
Max. Transmission power:
NF – power output:
Weight:
IP rating:
CE designation:
Channel frequency table
Channel
Frequency
1
446.00625
2
446.01875
3
446.03125
4
446.04375

8. Functional description / operating information

Please take the time to carefully read through this owner's manual to ensure
that you are familiar with all of the functions of your Ex-PMR 1000 and know
how to use them. For you own safety and information please read through the
information on the following pages.
32
-20 °C ... +50 °C
-20 °C ... +45 °C
0 °C ... +40 °C
Ex-battery pack Ex-AM PMR 1000
approx. 13 hours (90% standby, 5%TX, 5%RX)
approx. 4 hours
126 x 64 x 42 mm
446.00625 – 446.09375 MHz
approx. 0.30 µV at 12 dB SINAD
8
12.5 kHz
0.5W ERP
max. 0.5 W
approx. 450g (including battery pack)
IP 54
0102
0678
(MHz)
Frequency
Channel
(MHz)
5
446.05625
6
446.06875
7
446.08125
8
446.09375