Pay attention when using the equipment that the leather case is always
completely fastened.
- Only ECOM`s permitted equipment may be used.

5. Precautionary Advice

Electromagnetic waves can cause disturbance and can damage your health!
Since no defined statements can be made with reference to the interfering
immunity of the pacemakers, we recommend that pacemaker carriers refrain
from general contact with the radio transceiver.
Transmission should not take place in the vicinity of people with pacemakers!

6. Ex-Data

EG Certificate of Conformity no.:
EG Marking:
Authorised for zone 1 equipment group II, gas group C hazardous gasses, humidity
or mist, temperature class T4.

7. Technical Data

Surrounding temperature Ta:
Storage temperature:
Power supply:
Running duration:
Dimensions:
Weight:
IP Protective level:
Frequency range:
Reception switch:
Sensitivity:
Tuning framework:
Transmission power:
Secondary wavelength/harmonic: better than – 60 dB
NF – Initial performance:
CE Marking:
Radio admisson:
TÜV01 ATEX 1713X
II 2 G EEx ia IIC T4
-20...+50 deg C
-20...+60 deg C (without ex-accu pack)
Ex Accupack "AM500"
7-12 hours (90% standby, 5% TX, 5% RX)
58 x 145 x 27 mm (B x H x T)
about 410g (with accupack)
IP22
446,00625 – 446,09375 MHz
super double with 1.ZF 21,4 MHz and 2. ZF 455 kHz
about 0,20 µV for 12 dB SINAD
12,5 kHz
500 mW EIRP
max. 0,5 W on 16 Ohm
0102
ICT D801 459L
3