FX Supervisory Controller RS-485 Card
Applications
The RS-485 option card provides dual port, isolated
RS-485 communications capability to the FX
Supervisory Controllers. You can install up to two
RS-485 option cards per FX Supervisory Controller.
If an RS-485 option card is installed in Option Slot 1,
then the ports are COM3 and COM4. If an RS-485
option card is installed in Option Slot 2, then the ports
are COM3 and COM4 (unless the RS-232 option card
is installed in Option Slot 1). If the RS-232 option card
is installed in Option Slot 1, the RS-485 ports are
COM4 and COM5. See Table 1.
If two RS-485 option cards are installed, then the ports
are COM3 and COM4 for the card in Option Slot 1,
and COM5 and COM6 for the card is Option Slot 2.
For related information on FX Supervisory Controller
mounting and wiring, refer to the FX Supervisory
Controller Installation Instructions
(Part No. 24-10174-77).
Figure 1: FX Supervisory Controller RS-485 Card
© 2014 Johnson Controls, Inc.
Part No. 24-10174-69, Rev. C
Installation Instructions
Installation Instructions RS-485 Card
North American Emissions Compliance
United States
This equipment has been tested and found to comply
with the limits for a Class A digital device pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference when this equipment is operated in a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful
interference, in which case the user will be required to
correct the interference at his/her own expense.
Canada
This Class (A) digital apparatus meets all requirements
of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la Classe (A) respecte
toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Installation
Unpack the RS-485 option card and inspect the
contents of the package for damaged or missing
components. If the option card is damaged, notify the
appropriate carrier and return any damaged
components for repair or replacement.
Parts Included
Included in this package are the following items:
one RS-485 option card, along with connector end
plate
two 3-position terminal plugs, for wiring to two
RS-485 networks
FX Supervisory Controller RS-485 Card
Installation Instructions (Part No. 24-10174-69)
Issue Date April 9, 2014
www.johnsoncontrols.com
1

Advertisement

loading

Summary of Contents for Johnson Controls FX Supervisory Controller RS-485 Card

  • Page 1 If the option card is damaged, notify the appropriate carrier and return any damaged components for repair or replacement. Figure 1: FX Supervisory Controller RS-485 Card Parts Included Included in this package are the following items: ...
  • Page 2 3. Remove the battery and bracket assembly (if Special Tools Needed present) by taking out the four screws holding the The following supplies and tools are required for bracket in place. Set the screws aside for later. installation: 4. Unplug the battery from the connector on the FX ...
  • Page 3 If the RS-485 option card fails to operate within its specifications, replace the unit. For a replacement Wiring option card, contact the nearest Johnson Controls® Connect the RS-485 network communications wiring representative. to the 3-position connector of the RS-485 Card. The...
  • Page 4 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls® is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. © 2014 Johnson Controls, Inc. FX Supervisory Controllers RS-485 Card Installation Instructions...