New Shallow Well Installation; Installation For Surface Water; New Deep Well Installation; 4" Or Larger Well - Simer 2805E-01 Owner's Manual

Convertible deep well jet pumps and tank system
Table of Contents

Advertisement

Available languages

Available languages

New Shallow Well Installation

Relief
Valve
Check
Valve
Priming
Tee and
Plug
Foot
10'
Valve
Min.
5–10'
Screen
Figure 6:Typical Open Water
Installation

New Deep Well Installation

Relief
Valve
Drive Pipe
To Well
Suction Pipe
From Well
Well
Head
If well head and pump
ports don't match, twist
reinforced flexible pipe
to make connections.
Venturi
Not
Ejector
to
Scale
Nozzle
Foot Valve
Strainer
Figure 7:Typical 2" and 4" Deep Well
Installation
For parts or assistance, call Simer Customer Service at
INSTALLATION FOR SURFACE WATER (Figure 6)
To Household
1. The pump should be installed as close to the water as possible, with the
Water System
fewest possible fittings (especially elbows) in the suction pipe. The suc-
tion pipe should be at least as large as the suction port on the pump.
2. Assemble a foot valve and suction pipe. Make sure that the foot valve
Suction Pipe
works freely. Use Teflon tape
From Well
fish, trash, etc, by installing a screen around it.
3. Lower the pipe into the water until the strainer is five feet above the bot-
tom. It should also be at least 10 feet below the water level in order to
Not
prevent the pump from sucking air.
to
4. Install a priming tee, priming plug, and suction pipe to the pump.
Scale
Support the pipe so that there are no dips or sags in the pipe, so it does-
n't strain the pump body, and so that it slopes slightly upward from the
well to the pump (high spots can cause air pockets which can air lock
the pump). Seal the suction pipe joints with teflon tape. Joints must be
air and water tight. If the suction pipe can suck air, the pump cannot
pull water from the well.
4034 0801
4" OR LARGER WELL (Figure 7)
To Household
Water System
1. Install the control valve, the pressure gauge and the deep well injector
plug in the pump body. See Figure 2. Purchase Model MDWC Deep
Well Conversion Kit to obtain these parts.
2. Mount the pump as close to the well as possible.
3. Install a flexible pipe between the well head and the pump so the con-
nection will be correct. Connect small port to small port and large port
to large port.
NOTICE: Simer jet pumps have the suction port (the larger port) below
the drive port. See Figure 3.
4. Connect both the suction and drive pipes to the ejector piping and
lower the ejector into the well until it is five feet from the bottom. It
should also be at least 10 feet below the well's water level while the
pump is running in order to prevent the pump from sucking air.
5. Install a sanitary well seal and connect the ejector piping to the pump.
Use steel nipples through the well seal with flexible poly pipe to avoid
crushing the plastic pipe when tightening the seal.
6. Support the pipe so that there are no dips or sags in the pipe, so it does-
4035 0801
n't strain the pump body, and so that it slopes slightly upward from the
well to the pump (high spots can cause air pockets which can air lock
the pump). Seal the suction pipe joints with teflon tape. Joints must be
air- and water-tight. If the suction pipe can suck air, the pump cannot
pull water from the well.
. Protect the foot valve assembly from
TM
1-800-468-7867 / 1-800-546-7867
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

2806e-012810e-012815e-01

Table of Contents