Installation - Simer 2805E-02 Owner's Manual

Shallow well jet pumps
Hide thumbs Also See for 2805E-02:
Table of Contents

Advertisement

Available languages

Available languages

Installation

CASED WELL INSTALLATION,
2" OR LARGER CASING
Step 1. Mount the pump as close to the well as possible.
Step 2. Assemble the foot valve, strainer, and well pipe
(see Figure 2). Make sure that the foot valve
works freely.
Step 3. Lower the pipe into the well until the strainer is five
feet above the bottom of the well. It should also be
at least 10 feet below the well's water level while
the pump is running in order to prevent the pump
from sucking air. Install a sanitary well seal.
Step 4. Install a priming tee, priming plug, and suction
pipe to the pump (see Figure 2). Connect the pipe
from the well to the pump suction port, using the
fewest possible fittings – especially elbows – as
fittings increase friction in the pipe (however,
include a foot valve – see Figure 2). The suction
pipe should be at least as large as the suction
port on the pump. Use teflon tape or a teflon-
based pipe joint compound on threaded pipe
joints. Support the pipe so that there are no dips
or sags in the pipe, so it doesn't strain the pump
body, and so that it slopes slightly upward from
the well to the pump (high spots can cause air
pockets which can air lock the pump). Seal the
suction pipe joints with teflon tape or a teflon
based pipe joint compound. Joints must be air-
and water-tight. If the suction pipe can suck air,
the pump cannot pull water from the well.
You have just completed the suction piping for
your new shallow well jet pump. Please go to
Page 6 for discharge pipe and tank connections.
For parts or assistance, call Simer Customer Service at
(FIGURE 2)
To Household
Water System
Not
to
Scale
Figure 2: Cased Well Installation
1-800-468-7867 / 1-800-546-7867
Pump Priming
Tee and Plug
Suction Pipe
From Well
Priming
Tee and
Plug
Sanitary
Well Seal
Foot
10'
Min.
Valve
5–10'
5