Types Of Troubleshooting Information; Error Log - Omron SYSMAC CS Series Operation Manual

Customizable counter units
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Types of Troubleshooting Information

9-1

Types of Troubleshooting Information

Error Flags
Unit Error Codes

Error Log

Error occurs
9-2

Error Log

204
The Customizable Counter Unit records error information when an error
occurs in the Customizable Counter Unit or in the CPU Unit. The following
types of information are recorded in the Customizable Counter Unit.
One of the error flags will be turned ON to indicate when an error has
occurred.
There are two types of error codes: Special I/O Unit error codes and Custom-
izable Counter Unit error codes.
The Special I/O Unit error codes are general error codes used by the Special
I/O Units. These error codes are placed in the first word of an error record in
the error log. The Customizable Counter Unit error codes provide specific
information about Customizable Counter Unit errors. These error codes are
stored in SR 23500 to SR 23507, in the detailed information in the error log,
and in bits 00 to 07 of n+5 in the CIO Area words allocated in the CPU Unit.
Error Codes
Type
Special I/O Unit
All Special I/O
error codes
Units
Customizable
Only the
Counter Unit
Customizable
error codes
Counter Unit
An error record is created in the error log when an error occurs. Each error
record contains the Special I/O Unit error code, detailed information, and the
time read from the CPU Unit (see note). Up to 11 error records will be stored
in the error log, which is located in DM 6144 to DM 6199.
Note If the time cannot be accessed from the CPU Unit, all zeros will be stored for
the time.
Error flag(s) turned ON
Customizable Counter Unit
error code stored
Error record created
Note Refer to the manuals for the CS-series PLC for information on CPU Unit error
information.
The error log registers the error records for errors that occur in the Customiz-
able Counter Unit. The error information stored in the error log can be used for
troubleshooting.
Applicability
Storage location
First word of error log
record
SR 23500 to
SR 23507 and detailed
information in error log
Relevant flags turned ON
SR 23500 to SR 23507
Customizable Counter
Unit error code
Special I/O Unit error code
Details 1
Time of error
Note The Customizable Counter Unit
error code or other information
is stored for Details 2.
Section 9-1
Description
General error informa-
tion for Special I/O
Units
Specific error informa-
tion for Customizable
Counter Unit.
Details 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-hca12-v1Cs1w-hca22-v1Cs1w-hcp22-v1Cs1w-hio01-v1

Table of Contents