Use only the instructions and clearance dimensions on this
page for heaters to be installed in New Zealand.
The Regency F2402M has been tested by the AHHA Testing Laboratory
and conforms to AS/NZS 2918:2001, Report No. ATL19-04.
Tested on a pedestal base by AHHA Testing Laboratory (Report No,
ATL 19-04) and on legs by Applied Research (Report No. 05/1161).
Both tests conform to AS/NZ Standard 2918:2001.
MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
Residential Installation Clearances to Combustible Walls
Unit
Regency Vancouver F2402M
with Airmate* and Leg or Pedestal*
Tested with:
*Airmate fitted, and the flue kit must include a single skin 1200mm semi - circular stainless steel flue shield
fitted, installed with two flue mounted straps so that the bottom edge of the flue shield is approximately
10 mm above the top surface of the heater. A diverter clipped to the top of the shield angled forward and
up at 45°, should be fitted.
Please note attached flue kit specifications.
Flue systems tested:
Sheetmetal Fabricated Products Ltd.
PO Box 58 - 268 Greenmount, Auckland
New Zealand
Floor Protector:
6mm thick fibre cement sheet with thermal conductivity 0.41 W/m degree K underneath heater extending 300mm
in front and 200 mm from the sides of the firebox opening.
Regency Freestanding Woodstove
NEW ZEALAND ONLY
AUSTRALIA ONLY
From Unit
A
450mm
IMPORTANT
The Regency Vancouver F2402M has been tested with the flue
kits listed below. A default flue kit as listed in AS/NZS 2918:2001
may also be used.
These are the only flue kits certified for use with this heater for
installation in New Zealand.
From Corner
B
C
125mm
200mm
INSTALLATION
From Flue Center-Line
D
E
755mm
290mm
F
495mm
9