5.3.2

LIM (Signal monitoring)

Command
LIM
This command defines the pressure, which corresponds to 100 % of the input signal. If the demand is set
incorrectly, this leads to incorrect system settings, and the dependent parameters cannot be calculated
correctly.
Example:
LIM 500 (5% lower/upper limitation)
If the input signal gets higher than 95 % or lower than 5%, it leaves the permitted range and the output will
switch off.
5.3.3

R (Command signal ramp time)

Command
R:I
Two quadrant ramp function.
The ramp time is separately set for UP and DOWN ramps.
Page 18 of 24
Parameters
X
x= 0... 2000
100%
error range for
unipolar signals
0%
Parameter
X
i= UP|DOWN
x= 50... 10000
PAM-190-P-*-1010
Unit
0,01 %
Unit
ms
A:UP
Group
EXP
working
range
Group
STD
A:DOWN
t
18.08.2015