Parameters; Parameter Overview - WEST PAM-140-P Technical Documentation Manual

Universal mobile power amplifier
Table of Contents

Advertisement

5 Parameters

5.1 Parameter overview

Group
Command
Basic parameters
LG
MODE
Input signal adaptation
Signal scaling
AIN:W
Range monitoring
LIM
Ramp function
R:UP
R:DOWN
Output signal adaptation
MIN
MAX
TRIGGER
POL
Powerstage parameters
CURRENT
DFREQ
DAMPL
PWM
PPWM
IPWM
Page 15 of 24
Default
Unit
EN
-
STD
-
A:
1000
-
B:
1000
-
C:
0
0,01 %
X:
V
-
0
0,01 %
100
ms
100
ms
0
0,01 %
10000
0,01 %
200
0,01 %
+
-
0
-
120
Hz
0
0,01 %
488
Hz
1
-
40
-
PAM-190-P-*-1010
Description
Changing language help texts
Parameter view
Free scaling of the analogue input.
Signal monitoring function (e.g. joystick error)
Command signal ramp times
Deadband compensation
Output scaling
Deadband compensation trigger point
Output polarity
Current output range
Dither frequency
Dither amplitude
PWM frequency
Gain of the current loop
18.08.2015

Advertisement

Table of Contents
loading

Table of Contents