Chamberlain GAROG TST-2 Operational Description

Door control device

Advertisement

D
Funktionsbeschreibung
Operational description
GB
Description de fonctionnement
F
Descripción de funcionamiento
NL
TST-2
TST WS-B / 021016

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain GAROG TST-2

  • Page 1 Funktionsbeschreibung Operational description Description de fonctionnement Descripción de funcionamiento TST-2 TST WS-B / 021016...
  • Page 2 Funktionsbeschreibung Operational description Description de fonctionnement Descripción de funcionamiento TST-2 TST WS-B / 021016...
  • Page 3: Table Of Contents

    • Composition of the information given in this manual has been done to the best of our knowledge. Chamberlain GmbH does not guarantee the correctness of the details given in these instructions and may not be held liable for damages ensuing from incorrect installation.
  • Page 4: General Information On The Control Device

    Operational Description TST WS-B Page: 3 General information on the control device • Main application: industrial doors with electric drive (up to 2.2 kW, 400 VAC, AC-3) • mounted in the special door control housing TST GA with transparent cover for diagnostic. 4 LEDs: : Plug-in modules: 3 Poti:...
  • Page 5: Safety Instructions

    Operational Description TST WS-B Page: 4 Safety instructions During commissioning and operation of the control device the following important safety instructions and the subsequent mounting and connection instructions must be observed: • All installation, commissioning and maintenance work must be exclusively carried out by qualified specialist personnel.
  • Page 6: Mounting Of The Control Device

    Operational Description TST WS-B Page: 5 Mounting of the control device • Before mounting, the control device is to be checked for damage which may have occurred during transportation or for some other reason. Damage inside the control device can lead, under certain circumstances, to considerable subsequent damage to the control device and even pose a health risk for the user.
  • Page 7: Inputs / Outputs

    Operational Description TST WS-B Page: 6 Inputs / Outputs 5.1 Inputs Input Clamp Function Circuit feature to (DIP...) see chapter "Setting of types of operation" be connected 85-86 Pre-end switch security strip (DIP 6, 7) Closing device 83-84 End switch - intermediate holding operates upon all open commands Closing device (with membrane keypad OPEN can travel from intermediate holding position into upper end position)
  • Page 8: Commissioning

    Operational Description TST WS-B Page: 7 Commissioning The following introduction serves as directions for checking and setting door installations with mechanical end switches and contains some important observations which are to be considered. Familiarisation with the preceding chapter is a requirement. NB: When changing security strip systems, switch off the control device and after connection of the new system, set to setting operation (DIP1=On).
  • Page 9: Operation

    Operational Description TST WS-B Page: 8 Operation The main operating elements of the TST-WS-A door control device are in the top right corner of the plate when viewed straight on. Wire bridge P2 Wire bridge P3 DIP-switch (reversing time) (relay function K2) Note : Trimmer P1 Jumper 400...
  • Page 10: Display Door Cycle Counter

    Operational Description TST WS-B Page: 9 7.3 Display door cycle counter The door cycle counter counts the door movements from one end position into the other end position. It therefore provides information about the entire use of the door. This counter reading can be illustrated by the following button combination on the LEDs: •...
  • Page 11: Setting Of Types Of Operation (Dip Switches)

    Operational Description TST WS-B Page: 10 7.5 Setting of types of operation (DIP switches) The types of operation are set by DIP switches attached to the plate. The following table serves to describe the possible functions. DIP 1 Automatic Activate setting operation Dead man Only dead man function for opening and closing travel (without consideration of secu.
  • Page 12: Led Display Codes

    Operational Description TST WS-B Page: 11 7.6 LED display codes Colour Designation Indication of LED green Operational readiness Internal error recognised (eg. computer circuit)->switch control device on + off, or carry out reset function 0.15 Hz No automatic closing travel possible (3s ON/3s OFF) •...
  • Page 13: Technical Data

    Operational Description TST WS-B Page: 12 Technical data Housing dimensions (W X H X D): approx.: 182 x 320 x 93 mm (without mushroom-type button) Printed circuit board dimensions approx.: 210 x 170 x 70 mm (without plug-in module) (L x W x H): Mounting: standing vertically Supply:...
  • Page 14: Appendix A: Draw-In Security Device

    Note Operational Description TST WS-B Page: 13 The test of the draw-in security device happens only in the upper end position. For the realisation of an intermediate Appendix A: Draw-in security device stop ask your supplier. 9.1 Prinzip: operation +24V idle status: input IN6 (IN7) gets +24V EO-Test...
  • Page 15: Appendix B: Wiring Of Motor And End Switches ( Connection Example 1)

    Operational Description TST WS-B Page: 14 9.2 Appendix B: Wiring of motor and end switches 9.3 Appendix C: Wiring of motor and end switches (connection example 1) (connection example 2) Relay K1 Relay K1 F300 F300 1 AT 1 AT 17 N PE 5 6 7 8 11 N PE...
  • Page 16: Appendix D: Often Used Standard Connections

    Operational Description TST WS-B Page: 15 9.4 Appendix D: Often used standard connections em. stop11 em. stop12 em. stop21 em. stop22 SILEI Slot for radio module end open1 end open2 INKR end close1 end close2 Programming SiLei11 Microcontroller pin edge SiLei12 X502 SiLei21...
  • Page 17: Appendix E: Overview Tst Ws-B

    Operational Description TST WS-B Page: 16 9.5 Appendix E: Overview TST WS-B OPEN CLOSE F200 L extern 0,5Amp T L Alarm la. Alarm lamp N Alarmla. N Brake Brake N extern N supply PE supply PE extern PE extern K2 NO Fault message display, K2 Common yard light - pulse output...