Setting Of Types Of Operation (Dip Switches) - Chamberlain GAROG TST-2 Operational Description

Door control device
Table of Contents

Advertisement

Operational Description TST WS-B

7.5 Setting of types of operation (DIP switches)

The types of operation are set by DIP switches attached to the plate. The following table serves to describe the
possible functions.
DIP 1
Automatic
OFF
Dead man
ON
Automatic
DIP 2
Hold-open
time
OFF
inactive
ON
active
DIP 3
Min. hold-
open time
OFF
inactive
ON
active
DIP 4
Light barrier
function
OFF
Closing travel
ON
Opening and
closing travel
DIP 5
Pre-warning
OFF
inactive
ON
3s
DIP 6
Security
strip
OFF
Redund-ancy
ON
Testing
DIP 7
Pre-end
switch
OFF
Reverse
switch off
ON
Ignore
actuation
DIP 8
pre alarm
OFF
inactive
ON
3s
Wsb_bse8.doc
Activate setting operation
Only dead man function for opening and closing travel (without consideration of secu. strip,
object protection light barrier and ext. transmitters of open/close commands)
• Automatic opening travel, automatic closing travel when security strip present
• Automatic opening travel, dead man closing travel when security strip is
actuated/faulty
Automatic closing device, forced closing
no automatic closing device active
After reaching the upper end position (or intermediate holding) and after release of all opening
commands and security provisions the time set by the trimmer P1 begins. After the hold-open
time has expired, the door closes automatically. The hold-open time is interrupted by active
emergency stop or stop command. When the object protection light barrier, open command or
security strip is active, the hold-open time is kept at a maximum.
Interruption of the hold-open time
Function only active when hold-open time active (DIP2:on)
No minimum hold-open time active
• 2s after release of object protection light barrier, closing travel takes place
• When pre-warning active (see DIP 5), the pre-warning time runs directly from 3s.
Operating method of object protection light barrier
• During closing travel reversing
• During opening travel no function
• During closing travel reversing
• During opening travel as stop command. As long as actuation is set, only deadman travel is
possible. After release automatic opening travel (2s delay) takes place as far as the
corresponding previously requested end position (intermediate holding, upper end position). A
hold-open time which may have been set begins to run.
Warning light (relay K1) flashes only during opening and closing travel
Warning lamp flashes 3s before each movement, commencement of travel is delayed by 3s
Selection of the security principle according to prEN 12453
(see also clamping plans "security strip")
During the closing travel until activation of the lower pre-end switch or of the end switch both
independent signals of the security strip evaluation must always show the same signals. If
there is a signal change on one channel, the second channel must follow at the latest 100ms
later.
NB: must be activated in the case of pneumatic strips after activation of the lower pre-end
switch or when the lower end position switch is reached during/after closing travel, actuation of
the security strip is expected within 3s.
Behaviour of the door before and after activation of the pre-end switch
• Before activation: Actuation of the security strip effects immediate stop with subsequent
reopening travel
• After activation Actuation of the security strip effects immediate stop
• Before activation: Actuation of the security strip effects immediate stop with subsequent
reopening travel
• After activation: Actuation of security strip is ignored NB: during actuation there is no display
of the sec. strip LED
Behaviour of the alarm lamp before opening travel
• alarm lamp (relay K1) flashes while opening and closing
pre alarm for closing travel is dependant of DIP5
• alarm lamp flashes 3s before any opening travel (DIP 5 must be ON)
travel start will be delayed for 3 s
mt 041102