Operational Description TST WS-B
1
General information on the control device
•
Main application: industrial doors with electric drive (up to 2.2 kW, 400 VAC, AC-3)
•
mounted in the special door control housing TST GA with transparent cover for diagnostic.
Plug-in modules:
• 2-channel radio modul
TST SFFE2
(433 MHz FM)
• 2-channel Induction-
loop detector
TST SUVEK
• Safety edge evaluation
(during opening the door)
Sliding door function
TST SUKS/SSKS
Open, Stop, Close
(2 sets of 3-fold push button)
End switch upper and lower
2-fold emergency stop
security chain
(separate evaluation)
integrated
Safety edge evaluation
for door opening and closing
optional plug-in module
Safety edge evaluation
for door opening and closing
2x2 free clamp sites
(Passing of end switch
functions)
Digital Inputs 1...7
Pre-end switch
Intermediate holding
Impulse series control (single
channel)
Manual-/Automatic
Object protecting light barrier
2x draw in security devices with
testing
•
automatic or deadman opening and closing travel (closing travel in connection with closing edge security
device)
•
automatic closure after an adjustable hold-open time (1 ...320 s)
•
integrated safety edge evaluation (monitoring of door closing travel) with plug-in clamps for:
•
resistance monitoring (8.2/1.2 kΩ), N.C. or N.O. principle, selectively tested or redundant evaluation
("electrical" or "pneumatic" security strip)
•
evaluation of an optical safety edge (type: "Fraba-OSE")
•
door cycle counter (in steps of 10 via LEDs)
•
selectable reverse time (0.25s / 0.05s)
•
run time control 60s
Wsb_bse8.doc
4 LEDs: :
3 Poti:
Hold open time
Diagnostic LED (green)
Security-strip-LED (yellow)
Run time
Emergency-stop-LED (red)
supervision
Relay functions
Run-LED (green)
Loop detector/
Security strip
Closing
contactor
Opening
contactor
8 DIP-Switches:
Setting operation (dead man)
Hold open time
Min. hold open time
Light barrier function
Pre-warning before closing
Security strip evaluation
Pre-end switch behaviour
Pre-warning before opening
mt 041102
3-function foil key
Drive and break
(U, V, W, N, PE)
External supply 1
(L3, N (max. 1A))
External supply 2
(24VDC / 500mA regulated)
Warning light
(L3 (change-over contact), N)
Fault, door position,
traffic light function
(2x potential free change-over contact
Opening
(Potential free via contactor)
Closing
(Potential free via contactor)
3 x 400VAC
(L1, L2, L3, N, PE)
FEIG ELECTRONIC GmbH
Page: 3