Operational Description TST WS-B
7.3 Display door cycle counter
The door cycle counter counts the door movements from one end position into the other end position. It therefore
provides information about the entire use of the door. This counter reading can be illustrated by the following button
combination on the LEDs:
•
Press emergency switch-off mushroom-type button
•
Press OPEN membrane button and keep pressed
•
Press CLOSE membrane button
•
The buttons can now be released
As a starting symbol of the output all 4 LEDs light up for approx. 0.5s. The door cycle counter is now displayed
according to the diagram below. The display begins with the highest-value LED.
Example:
A door cycle counter reading/maintenance cycle counter reading of 63856 is displayed in the following sequence:
•
6x flashes of the Run-LED
•
3x flashes of the Sec. Strip-LED (3x 1000 = 3000)
•
8x flashes of the Emerg. stop-LED
•
5x flashes of the Incr.-LED
The last position is not dipslayed.
->This display mode can be exited by pulling the emergency switch-off button.
7.4 Carrying out reset function
The reset function serves to restart the control device without shutting off the power supply. By means of this
function errors can be cancelled. The counter readings and functions set thus remain unaltered.
Press foil key STOP, OPEN and CLOSE together -> control device restarts
Wsb_bse8.doc
Run
SiLei
NotSt
(green)
(orange)
(red)
Fig. 8.3: Output of the counter readingson the LEDs
(6 x 10000 = 60000)
(8x 100 =
(5x 10
Pulse number (flashing)x10000
Pulse number (flashing)x1000
Pulse number (flashing)x100
Pulse number (flashing)x10
Inkr
(green)
800)
=
50)
mt 041102
Page: 9
FEIG ELECTRONIC GmbH