Inputs / Outputs - Chamberlain GAROG TST-2 Operational Description

Door control device
Table of Contents

Advertisement

Operational Description TST WS-B
5

Inputs / Outputs

5.1 Inputs
Input
Clamp
IN1
85-86
IN2
83-84
IN3
81-82
IN4
74-75
IN5
71-72
IN6
65-66
IN7
61-62
Emergen-cy
31-32
stop 1
Emergen-
33-34
cy stop 2
Upper end
35-36
Lower end
37-38
51-
Stop ext 1
52
Open ext 1
55
Close ext 1
57
53-
Stop ext 2
54
Open ext 2
56
Close ext 2
58
Sec. strip
42-44
21/22
Radio mod
-
chan. 1+2
Sec. strip
40-41
11/12
Det 1/2
Connec.
directly
on
detector
*1: if this input is not used, an appropriate wire bridge must be inserted
*2: bridged ex works
5.2 Outputs
Output
Clamp
Relay K1
2-N
Relay K2
11-12-
13
OPEN-
13-14
contactor
CLOSE-
13-14
contactor
Wsb_bse8.doc
Function
(DIP...) see chapter "Setting of types of operation"
Pre-end switch security strip (DIP 6, 7)
End switch - intermediate holding operates upon all open commands
(with membrane keypad OPEN can travel from intermediate holding
position into upper end position)
Pulse series - Input: OPEN->STOP->CLOSE->STOP
(no automatic closing travel after expiring of hold-open time)
Object protection - light barrier 1
automatic opening travel, deadman closing travel permitted.
Switch over deadman/automatic when actuating (interrupting) deadman
operation each new actuation firstly causes a stop
Draw-in security device 1: during actuation: locking the opening travel,
deadman closing travel
Draw-in security device 2: see draw-in security device 1
Emergency stop chain 1
actuation at beginning of closing travel from upper end position effects an
automatic return approach )
Emergency stop chain 2
*1
Upper end switch
*1
Lower end switch
Three-function push button 1
*1
STOP
: no travel possible
OPEN: automatic opening travel, no deadman function (DIP 2)
CLOSE: automatic closing travel, no deadman function
Three-function push button 2
*1
STOP
: no travel possible
OPEN: automatic opening travel, no deadman function (DIP 2)
CLOSE: automatic closing travel, no deadman function
Security strip (via integrated evaluator) during actuation or fault:
during closing travel: reversing (stop->opening travel)
general: closing travel still possible in deadman operation only
channel 1 : OPEN->STOP->CLOSE->STOP
channel 2: OPEN->EO->CLOSE->OPEN
Additional security strip (via plug-in module) during actuation or fault:
during closing travel: reversing: STOP->closing for 0,5 sec.->STOP
general: closing travel still possible in deadman operation only
2-channel induction loop detector (via plug-in module)
while actuation effects:
general opening
while closing->reversal
Function
Warning light, flashes during travel and between the end positions.
Exception: Emergency stop and deadman operation (see also DIP 5)
Fault indication output/ yard light function: *see wirebridge P3)
Indication of opening travel active
Indication of closing travel active
*1
: (DIP 2, 3, 4) when actuated:
*1
: Slack rope switch, slip door (short-term
*1
: Emergency end switch, thermoplate,...
mt 041102
Page: 6
Circuit feature to
be connected
Closing device
Closing device
Closing device
Opening device
Opening device
Opening device
with testing
enclosure D)
Opening device
with testing
Opening device
Opening device
Opening device
Opening device
Opening device
Closing device
Closing device
Opening device
Closing device
Closing device
-
-
-
-
Switching feature
Closing device,
230 V switching
Change-over
contact, potential-
free
Closing device,
potential-free
Closing device,
potential-free
FEIG ELECTRONIC GmbH
*2
*2
*2
(see
*2
*2
*2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Garog tst ws seriesGarog tst ws-bGarog tst ws-a

Table of Contents