Safety Instructions - Chamberlain GAROG TST-2 Operational Description

Door control device
Table of Contents

Advertisement

Operational Description TST WS-B
2

Safety instructions

During commissioning and operation of the control device the following important
safety instructions and the subsequent mounting and connection instructions
must be observed:
• All installation, commissioning and maintenance work must be exclusively carried out
by qualified specialist personnel. In particular, the following regulations must be ob-
served (without this list being exhaustive): VDE regulations (VDE 0100, VDE 0105,
VDE 0113, VDE 0160, VDE 0700), fire prevention regulations, accident prevention
regulations and the relevant regulations for industrial doors (ZH1/494, prEN12453,
prEN12978)
• The control device must only be opened when power is switched off at all poles.
• The control device must not be operated in the open condition.
• The control device may be operated with the CEE plug disassembled only if the mains
power supply can be isolated from the control device at all poles by means of an
appropriate switch.
• The control device must not be operated with a defective membrane keypad.
Damaged keypads must be replaced. The keypad is basically provided only for finger
operation. It should not be operated with sharp objects.
• Before the control device power supply is switched on for the first time, it must be en-
sured that all insert cards are correctly placed in the insertion spaces provided for
them.
• When the door is moving in deadman operation it is to be ensured that the door region
can be seen by the operator since, in this type of operation, security devices such as
the security strip and light barriers can be bypassed.
• The manual operation of the contactors is prohibited. The guarantee becomes void if
the protective foil is destroyed.
• According to prEN12453 the pre-end switch of the security strips may be positioned at
a maximum of 50mm above the lower end position. The details given in the chapter
• Clamping and connection plan for the security strip" are to be strictly followed.
• Check the setting of all DIP switches and operation of the security devices.
Failure to comply with safety instructions can result in a risk to health or to the control
device being damaged.
These safety instructions are not intended to be exhaustive. Please discuss any queries
with your supplier.
The manufacturer has carefully checked the device hardware and software and the
product documentation but cannot provide any guarantee against errors.
The serial number is applied on a separate sticker to the printed circuit board and to the
control housing. For motor dates (nominal load and torque, etc) construction year and
additional information, please read the technical information of motor and door.
Wsb_bse8.doc
TST WS
Control Device
3N~400V / ~230V
50...60Hz / 2500W
IP54 (IP65) / -10...+50°C
mt 041102
Page: 4