Close the front cover with the key.
13
Turn the TeraStation off first, then turn it on while holding down the mode button.
14
"RAID-0 NORMAL" will be displayed on the LCD panel.
RAID-0
NORMAL
15
Create a volume by referring to the "Creating a Volume" section in chapter 3.
For RAID 6 or RAID 10 Volumes:
1
Open the front cover with the included key.
2
Check the status LEDs. The LED for the failed drive glows amber.
3
Pull out two drive cartridges whose status LED glow amber and remove them from the TeraStation. Leave the
drives whose status LEDs blink amber in the TeraStation.
Do not unplug and remove the drives with the status LED lit green. If you do, it may cause data loss or
the TeraStation to malfunction.
4
Turn off the TeraStation. It may take some time until the shutdown process completes.
5
Turn on the TeraStation while holding down the mode button with the drives left removed.
6
When either the "RAID-x TWO DRIVE DOWN" message or the "MULTIPLE DOWN" message is displayed, replace
the defective drive by referring to the ""TWO DRIVE DOWN" or "MULTIPLE DOWN" Is Displayed on the LCD
Panel" section above.
If "SYSTEM DOWN" is still displayed, go to the next step to replace more defective drives.
7
Pull out other defective drive cartridges whose status LED glows amber and remove them from the
TeraStation.
8
Remove drives from the cartridges and install new drives in them.